Summary

Excerpt

The FDA anthropomorphic thorax phantom with 12 phantom lesions of different sizes (10 and 20 mm in effective diameter), shapes (spherical, elliptical, lobulated, and spiculated), and densities (−630,−10, and +100 HU) was scanned at Columbia University Medical Center on a 64-detector row scanner (LightSpeed VCT, GE Healthcare, Milwaukee, WI). The CT scanning parameters were 120 kVp, 100 mAs, 64x0.625 collimation, and pitch of 1.375. The images were reconstructed with the lung kernel using 1.25 mm slice thickness.

This data set was provided to TCIA for use in the National Cancer Institute's Quantiatitive Imaging Network (QIN) Lung CT Segmentation Challenge.  A TCIA

...

Analysis Result dataset was created to enable easy re-use of the complete multi-site challenge data set.

About the NCI QIN

The mission of the QIN is to improve the role of quantitative imaging for clinical decision making in oncology by developing and validating data acquisition, analysis methods, and tools to tailor treatment for individual patients and predict or monitor the response to drug or radiation therapy. More information is available on the Quantitative Imaging Network Collections page. Interested investigators can apply to the QIN at: Quantitative Imaging for Evaluation of Responses to Cancer Therapies (U01).

...

Localtab Group



Localtab
activetrue
titleData Access

Data Access

...


Data

...

TypeDownload all or Query/FilterLicense
Images (DICOM, 127.5 MB)

...


Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/19038256/TCIA_Lung_Phantom_06-22-2015.tcia?version=2&modificationDate=1601061652295&api=v2

Download Lung Phantom


Tcia button generator
labelSearch
urlhttps://nbia.cancerimagingarchive.net/nbia-search/?MinNumberOfStudiesCriteria=1&CollectionCriteria=Lung Phantom

Search Lung Phantom

  

(Download requires the NBIA Data Retriever)

Tcia cc by 3

DICOM Metadata Digest (CSV, 28 kB)

...


Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/19038256/LungPhantom_MetaData.csv?version=1&modificationDate=1495563917555&api=v2



Tcia cc by 3


Click the Versions tab for more info about data releases.

Nci_crdc additional resources

Third Party Analyses of this Dataset

TCIA encourages the community to publish your analyses of our datasets. Below is a list of such third party analyses published using this Collection:




Localtab
titleDetailed Description

Detailed Description


Collection Statistics

Updated 2014/08/26

Modalities

CT

Number of

...

Participants

1

Number of Studies

1

Number of Series

1

Number of Images

237

Image Size (MB)127.5

Supporting Documentation and Metadata

No supporting documentation is available for this collection.





Localtab
titleCitations & Data Usage Policy

Citations & Data Usage Policy 

This collection is freely available to browse, download, and use for commercial, scientific and educational purposes as outlined in the Creative Commons Attribution 3.0 Unported License. See TCIA's Data Usage Policies and Restrictions for additional details. Questions may be directed to help@cancerimagingarchive.net.

Please be sure to include the following citations in your work if you use this data set:

Tcia limited license policy

Info
titleData Citation

Zhao,

...

B. (2015).

...

Lung

...

Phantom (Version 2) [Data set]. The Cancer Imaging Archive.

...

https://doi.org/10.7937/

...

k9/

...

tcia.2015.

...

08a1ixoo


Info
titleTCIA Citation

Clark, K., Vendt, B., Smith, K., Freymann, J., Kirby, J., Koppel, P., Moore, S., Phillips, S., Maffitt, D., Pringle, M., Tarbox, L., & Prior, F.

...

(2013). The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository

...

. In Journal of Digital Imaging

...

(Vol. 26,

...

Issue 6,

...

pp

...

.

...

titleQIN Challenge DOI Citation

...

1045–1057). Springer Science and Business Media LLC. https://doi.org/10.

...

1007/s10278-013-9622-7 PMCID: PMC3824915


Other Publications Using This Data

TCIA maintains a list of publications

...

which leverage our

...

data.

...

If you have

...

a publication you'd like to add, please

...

contact TCIA's Helpdesk .




Localtab
titleVersions

Version

...

2 (Current): Updated

...

2020/

...

09/

...

25

Data TypeDownload all or Query/Filter

...

CT(127.5 MB)

...

Image Removed Image Removed

...


Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/19038256/LungPhantom_MetaData.csv?version=1&modificationDate=1495563917555&api=v2



Tcia button generator
labelSearch
urlhttps://www.cancerimagingarchive.net/nbia-search/?CollectionCriteria=Lung%20Phantom


  

(Download requires the NBIA Data Retriever)

DICOM Metadata Digest (CSV)

...


Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/19038256/LungPhantom_MetaData.csv?version=1&modificationDate=1495563917555&api=v2



9/25/2020: Adjusted this table and *.tcia manifest files to remove segmentations built in Multi-site collection of Lung CT data with Nodule Segmentations. DOI: https://doi.org/10.7937/K9/TCIA.2015.1BUVFJR7 . Note that the "Search" will take you to both until you uncheck the "Include third party" button.

Version 1: Updated 2014/08/26

(deprecated)