Child pages
  • Low Dose CT Image and Projection Data (LDCT-and-Projection-data)

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...


Localtab Group


Localtab
activetrue
titleData Access

Data Access

Click the  Download button to save a ".tcia" manifest file to your computer, which you must open with the NBIA Data Retriever . Click the Search button to open our Data Portal, where you can browse the data collection and/or download a subset of its contents.

Data TypeDownload all or Query/Filter
Images (DICOM, 1.23 TB)

 

(Requires NBIA Data Retriever)

Images (DICOM, 2.0 GB) - Phantom Object Only

 

DICOM-CT-PD User Manual Version 3 (.pdf)

Matlab DICOM-CTPD data dictionary (.txt)

Matlab DICOM-CTPD reader script (.txt)

Clinical Data (CSV, zip)

Click the Versions tab for more info about data releases.


Localtab
titleDetailed Description

Detailed Description

Image Statistics


Modalities

CT

Number of Participants

300

Number of Studies

599

Number of Series

1048

Number of Images

13,027,273

Images Size (TB)1.23


For each patient CT scan, three types of data are provided: DICOM-CT-PD projection data, DICOM image data, and Excel clinical data reports. CT projection data are provided for both full and simulated lower dose levels and CT image data reconstructed using the commercial CT system are provided for the full dose projection data. For patients scanned on the SOMATOM Definition Flash CT scanner from Siemens Healthcare, CT image data reconstructed using the commercial CT system are also provided for the lower dose projection data. All CT images were reconstructed using a filtered back projection method. Several instructional documents are provided to help users extract needed information from the DICOM-CT-PD files, including a dictionary file for the DICOM-CT-PD format, a DICOM-CT-PD reader, and a user manual.

This collection comprises 99 head scans (labeled N for neuro), 100 chest scans (labeled C for chest), and 100 abdomen scans (labeled L for liver). Fifty cases for each scan type are from a SOMATOM Definition Flash CT scanner (Siemens Healthcare, Forchheim, Germany). Forty-nine head cases, 50 chest cases, and 50 abdomen cases are from a Lightspeed VCT CT scanner (GE Healthcare, Waukesha, WI). Together, these data will greatly facilitate the development and validation of new CT reconstruction and/or denoising algorithms, including those associated with machine learning or artificial intelligence.

Acquisition protocol

All CT scans were acquired at routine dose levels for the practice at which they were obtained using standard-clinical protocols for the anatomical region of interest. Each clinical case was processed to include a second projection dataset at a simulated lower dose level.  Head and abdomen cases are provided at 25% of the routine dose and chest cases are provided at 10% of the routine dose.

1Additional information regarding the CT projection data format: Chen B, Duan X, Yu Z, Leng S, Yu L, McCollough CH. Technical Note: Development and validation of an open data format for CT projection data. Med Phys. 2015;42(12):6964. (doi: https://doi.org/10.1118/1.4935406.)


Localtab
titleCitations & Data Usage Policy

Citations & Data Usage Policy

These collections are freely available to browse, download, and use for commercial, scientific and educational purposes as outlined in the Creative Commons Attribution 3.0 Unported License. See TCIA's Data Usage Policies and Restrictions for additional details. Questions may be directed to help@cancerimagingarchive.net.

Please be sure to acknowledge both this data set and TCIA in publications by including the following citations in your work:
Public collection license
Info
titleData Citation

McCollough, C.H., Chen, B., Holmes, D., III, Duan, X., Yu, Z., Yu, L., Leng, S., Fletcher, J. (2020). Data from Low Dose CT Image and Projection Data [Data set]. The Cancer Imaging Archive.  https://doi.org/10.7937/9npb-2637


Info
titleGrant Citation

Presentations and publications shall acknowledge grants EB017095 and EB017185 (Cynthia McCollough, PI) from the National Institute of Biomedical Imaging and Bioengineering.


Info
titleTCIA Citation

Clark K, Vendt B, Smith K, Freymann J, Kirby J, Koppel P, Moore S, Phillips S, Maffitt D, Pringle M, Tarbox L, Prior F. The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository, Journal of Digital Imaging, Volume 26, Number 6, December, 2013, pp 1045-1057. DOI: 10.1007/s10278-013-9622-7

Other Publications Using This Data

TCIA maintains a list of publications which leverage TCIA data. If you have a manuscript you'd like to add please contact the TCIA Helpdesk.


Localtab
titleVersions

Version 1 (Current): Updated 2020/04/22

Data Type Download all or Query/Filter
Images (DICOM, 1.23 TB)

 

Download button not active

(Requires NBIA Data Retriever .)

Images (DICOM, 2.0 GB)

Phantom Object Only

 

DICOM-CT-PD User Manual Version 3 (.pdf)


Matlab DICOM-CTPD data dictionary (.txt)

Matlab DICOM-CTPD reader script (.txt)

Clinical Data (CSV, zip)




...