Child pages
  • Variations of dynamic contrast-enhanced magnetic resonance imaging in evaluation of breast cancer therapy response: a multicenter data analysis challenge (QIN Breast DCE-MRI)

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Next »

Summary

This collection of breast dynamic contrast-enhanced (DCE) MRI data contains images from a longitudinal study to assess breast cancer response to neoadjuvant chemotherapy. Images were acquired at four time points: prior to the start of treatment (Visit 1, V1), after the first cycle of treatment (Visit 2, V2), at midpoint of treatment course (Visit 3, V3), and after completion of treatment (prior to surgery) (Visit 4, V4). The value of this collection is to provide clinical imaging data for the development and validation of quantitative imaging methods for assessment of breast cancer response to treatment. Data is provided by Oregon Health & Science University, PI Dr. Wei Huang.

The MRI data consist of DCE-MRI images, which were acquired using a Siemens 3T TIM Trio system with the body coil and a four-channel bilateral phased-array breast coil as the transmitter and receiver, respectively.  Following pilot scans and pre-contrast T2-weighted MRI with fat-saturation and T1-weighted MRI without fat-saturation, axial bilateral DCE-MRI images with fat-saturation and full breast coverage were acquired with a 3D gradient echo-based TWIST (Time-resolved angiography WIth Stochastic Trajectories) sequence, which employs the strategy of k-space undersampling during acquisition and data sharing during reconstruction.  DCE-MRI acquisition parameters included 10o flip angle, 2.9/6.2 ms TE/TR, a parallel imaging acceleration factor of two, 30-34 cm FOV, 320x320 in-plane matrix size, and 1.4 mm slice thickness.  The total acquisition time was ~10 minutes for 32-34 image volume sets of 112-120 slices each with 18-20 s temporal resolution.  The contrast agent Gd(HP-DO3A) [ProHance] IV injection (0.1 mmol/kg at 2 mL/s) by a programmable power injector was timed to commence after acquisition of two baseline image volumes, followed by a 20-mL saline flush.          

A total of 20 data sets from this collection have been used for a multi-QIN center challenge, in which each participating site performed pharmacokinetic analysis of the breast DCE-MRI data using software tools/algorithms available to them. The shared data sets are from the V1 and V2 studies of 10 patients (BreastChemo 1, 5, 6, 8, 10, 12, 13, 14, 15, and 16) – 3 pathologic complete responders (pCRs) and 7 non-pCRs.  The goal of the challenge was to evaluate variations in DCE-MRI assessment of breast cancer response to neoadjuvant chemotherapy caused by differences in software tools/algorithms only. 

If your use of this collection results in a publication, we would appreciate if you cite the appropriate references and acknowledge the award that supported collection and sharing of these data sets (U01 CA154602, PI Wei Huang).  Please see the published paper for details of the challenge.

Reference
Huang W, Li X, Chen Y, Li X, Chang MC, Oborski MJ, Malyarenko DI, Muzi M, Jajamovich GH, Fedorov A, Tudorica A, Gupta SN, Laymon CM, Marro KI, Dyvorne HA, Miller JV, Barbodiak DP, Chenevert TL, Yankeelov TE, Mountz JM, Kinahan PE, Kikinis R, Taouli B, Fennessy F, Kalpathy-Cramer J.  Variations of dynamic contrast-enhanced magnetic resonance imaging in evaluation of breast cancer therapy response: a multicenter data analysis challenge.  Trans Oncol 2014;7:153-166. PubMed PMID: 24772219; PubMed Central PMCID: PMC3998693. (link)

About the NCI QIN

The mission of the QIN is to improve the role of quantitative imaging for clinical decision making in oncology by developing and validating data acquisition, analysis methods, and tools to tailor treatment for individual patients and predict or monitor the response to drug or radiation therapy. More information is available on the Quantitative Imaging Network Collections page. Interested investigators can apply to the QIN at: Quantitative Imaging for Evaluation of Responses to Cancer Therapies (U01) PAR-11-150.

Data Access

Imaging Data

Icon

You can view and download these images on The Cancer Imaging Archive (TCIA) by logging in and selecting the QIN Breast DCE-MRI collection.

Collection Statistics

(updated 7/2/2014)

Modalities

MR, KO

Number of Patients

10

Number of Studies

20

Number of Series

672

Number of Images

76,328

If you are unsure how to download this collection, please view Searching by Collection or refer to our TCIA's User's Guide for more detailed instructions on using the site.

Shared Lists

  • Coming soon

Clinical Data

Pathologic response status for the patients:

  • Complete response
    • QIN-Breast-DCE-MRI-BC05
    • QIN-Breast-DCE-MRI-BC06
    • QIN-Breast-DCE-MRI-BC15
  • Non-complete response
    • QIN-Breast-DCE-MRI-BC01
    • QIN-Breast-DCE-MRI-BC08
    • QIN-Breast-DCE-MRI-BC10
    • QIN-Breast-DCE-MRI-BC12
    • QIN-Breast-DCE-MRI-BC13
    • QIN-Breast-DCE-MRI-BC14
    • QIN-Breast-DCE-MRI-BC16

 

  • No labels