Summary

The RIDER Phantom PET-CT collection consists of repeat measurement PET/CT phantom scan collections carried out under the aegis of the Society of Nuclear Medicine (SNM) to discern the uniformity of clinical imaging instrumentation at various sites. They were obtained in cooperation with SNM as a resource for increased quantitative understanding of machine acquisition, analytic reproducibility and image processing.

The phantom was manufactured by Sanders Medical (www.sandersmedical.com) in December of 2006. The phantom was based on a NEMA NU-2 IQ phantom (manufactured by Data Spectrum, Durham NC), but with the central 5 cm diameter 'lung' cylinder of the IQ phantom removed. In addition the two larger fillable spheres were changed to hot spheres, as opposed to cold spheres as in the NEMA NU-2 specifications. Nominal target/background ratio was 4:1 with the initial background activity level set to be equivalent to 15 mCi in a 70 Kg patient, With the 271 day half-life of Ge-68 after 6 months the activity will be about 9.5 mCi. After a year it was 6 mCi.


About the RIDER project

The Reference Image Database to Evaluate Therapy Response (RIDER) is a targeted data collection used to generate an initial consensus on how to harmonize data collection and analysis for quantitative imaging methods applied to measure the response to drug or radiation therapy.  The National Cancer Institute (NCI) has exercised a series of contracts with specific academic sites for collection of repeat "coffee break," longitudinal phantom, and patient data for a range of imaging modalities (currently computed tomography [CT] positron emission tomography [PET] CT, dynamic contrast-enhanced magnetic resonance imaging [DCE MRI], diffusion-weighted [DW] MRI) and organ sites (currently lung, breast, and neuro). The methods for data collection, analysis, and results are described in the new Combined RIDER White Paper Report (Sept 2008):

The long term goal is to provide a resource to permit harmonized methods for data collection and analysis across different commercial imaging platforms to support multi-site clinical trials, using imaging as a biomarker for therapy response. Thus, the database should permit an objective comparison of methods for data collection and analysis as a national and international resource as described in the first RIDER white paper report (2006):



Data Access

Data TypeDownload all or Query/FilterLicense
Images (DICOM, 689 MB)






(Download requires the NBIA Data Retriever)

DICOM Metadata Digest (CSV, 10 kB)




Annotation Data (DOC)




Click the Versions tab for more info about data releases.


Detailed Description

Collection Statistics

Radiology Image Statistics

Modalities

CT, PET

Number of Patients

20

Number of Studies

20

Number of Series

60

Number of Images

2,231

Image Size (MB)689

Additional annotation data about this collection can be viewed in the following document: Ge68Phantom_2015.doc.



Citations & Data Usage Policy 

Muzi, P., Wanner, M., & Kinahan, P. (2015). Data From RIDER PHANTOM PET-CT (Version 2) [Data set]. The Cancer Imaging Archive. https://doi.org/10.7937/K9/TCIA.2015.8WG2KN4W


Clark, K., Vendt, B., Smith, K., Freymann, J., Kirby, J., Koppel, P., Moore, S., Phillips, S., Maffitt, D., Pringle, M., Tarbox, L., & Prior, F. (2013). The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository. In Journal of Digital Imaging (Vol. 26, Issue 6, pp. 1045–1057). Springer Science and Business Media LLC. https://doi.org/10.1007/s10278-013-9622-7 PMCID: PMC3824915


Other Publications Using This Data

TCIA maintains a list of publications which leverage our data. If you have a publication you'd like to add please contact TCIA's Helpdesk.


Version 2 (Current): Updated 2015/01/26


Data TypeDownload all or Query/Filter
Images (DICOM, 689 MB)






(Download requires the NBIA Data Retriever)

DICOM Metadata Digest (CSV)




Annotation Data (DOC)




The Annotation Data document was updated with new information.

Version 1: Updated 2011/09/11

Original data upload.