Summary

This collection of soft-tissue sarcoma dynamic contrast-enhanced (DCE) MRI data contains images from a longitudinal study to assess soft-tissue sarcoma response to preoperative chemoradiation treatment. Images were acquired at three time points: prior to the start of treatment (Visit 1, V1), after the first cycle of chemotherapy (Visit 2, V2), and after ~ 8 more weeks of chemoradiation (prior to surgery) (Visit 3, V3).  Not every patient was able to complete all three MRI studies. The value of this collection is to provide clinical imaging data for the development and validation of quantitative imaging methods for assessment of soft-tissue sarcoma response to preoperative treatment.  Initial findings of this study have been published and the data is provided by Oregon Health & Science University, PI Dr. Wei Huang.

The MRI data consist of DCE-MRI images only, which were acquired using a Siemens 3T TIM Trio system with the body coil as the transmitter and a body matrix phased array (combined with a spine matrix phased array) coil as the receiver. Following scout and axial T2-weighted MRI, a RF-spoiled gradient-echo sequence was used to acquire sagittal DCE-MRI images covering the entire tumor, with 100 flip angle, TE/TR = 1.5/6.0 ms, 24-26 cm field of view (FOV), and 5 mm slice thickness with 1 mm gap. A parallel imaging acceleration factor of 2 was used for DCE-MRI, resulting in 7-16 s temporal resolutions depending on tumor size. The total DCE acquisition time was approximately 10 min with gadolinium contrast agent (Prohance®) IV injection (0.1 mmol/kg at 2 mL/s) carried out following acquisition of five baseline image volumes,  followed by a 20-mL saline flush.       

 


Data Access

This is a limited access data set. To request access, please contact help@cancerimagingarchive.net. Once access is granted, click the Download button to save a ".tcia" manifest file to your computer, which you must open with the NBIA Data Retriever. Click the Search button to open our Data Portal, where you can browse the data collection and/or download a subset of its contents.

Data TypeDownload all or Query/Filter
Images (DICOM, 10.29GB)

 

Click the Versions tab for more info about data releases.


Detailed Description

Collection Statistics

 

Modalities

MR

Number of Patients

15

Number of Studies

38

Number of Series

2,168

Number of Images

46,614

Image Size (GB)10.29



Citations & Data Usage Policy 

This is a limited access data set. Upon receiving access you may only use it for the purposes outlined in your request to the data provider. You are not allowed to redistribute the data or use it for other purposes. See TCIA's Data Usage Policies and Restrictions for additional details. Questions may be directed to help@cancerimagingarchive.net.

Please be sure to include the following citations in your work and acknowledge the award that supported collection and sharing of these data sets (U01 CA154602, PI Wei Huang) if you use this data set:

Huang, Wei, Ryan, Christopher, Beckett, Brooke, Tudorica, Alina, Mansoor, Atiya, Afzal, Aneela, … Aston, Torrie. (2016). Data From QIN-SARCOMA. The Cancer Imaging Archive. http://doi.org/10.7937/K9/TCIA.2016.fXL9sESs


Meyer JM, Perlewitz KS, Hayden JB, Doung YC, Hung AY, Vetto JT, Pommier RF, Mansoor A, Beckett BR, Tudorica A, Mori M, Holtorf ML, Afzal A, Woodward WJ, Rodler ET, Jones RL, Huang W, Ryan CW.  Phase I trial of preoperative chemoradiation plus Sorafenib for high risk extremity soft tissue sarcoma with dynamic contrast-enhanced magnetic resonance imaging correlates.  Clin Cancer Res 2013 Dec;19(24):6902-6911. PubMed PMID: 2413292; PubMed Central PMCID: PMC3869565 (link)


Clark K, Vendt B, Smith K, Freymann J, Kirby J, Koppel P, Moore S, Phillips S, Maffitt D, Pringle M, Tarbox L, Prior F. The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository, Journal of Digital Imaging, Volume 26, Number 6, December, 2013, pp 1045-1057. (paper)

Other Publications Using This Data

TCIA maintains a list of publications that leverage our data. At this time we are not aware of any additional publications based on this data. If you have a publication you'd like to add, please contact the TCIA Helpdesk.


Version 1 (Current): Updated 2014/09/04

Data TypeDownload all or Query/Filter
Images (DICOM, 10.29GB)

 

(Download requires the NBIA Data Retriever.)