Localtab |
---|
active | true |
---|
title | Data Access |
---|
| Data Access
Data Type | Download all or Query/Filter | License |
---|
Segmentation (NIfTI, zip, 4 MB) | Tcia button generator |
---|
url | https://wiki.cancerimagingarchive.net/download/attachments/70222123/DRO%20Toolkit-3%20Subjects%20SEG%20and%20QIN%20multi-site%2010%20Subjects%20SEG%20NIfTI.zip?api=v2 |
---|
|
|
| | Feature Variability Software Package details (xlsx, 13 kb) | Tcia button generator |
---|
url | https://wiki.cancerimagingarchive.net/download/attachments/70222123/Table%201%20-%20Feature%20Variability%20Software%20Details_v2.xlsx?api=v2 |
---|
|
|
| | DRO Results (xlsx, 31 kb) | Tcia button generator |
---|
url | https://wiki.cancerimagingarchive.net/download/attachments/70222123/DRO%20Results%20Table%202%20QIN%20PET%20CT%20WG%20DRO%20Feature%20Values_Table2_supporting_data.xlsx?api=v2 |
---|
|
|
| | Patient Dataset Results (xlsx, 400 kb) | Tcia button generator |
---|
url | https://wiki.cancerimagingarchive.net/download/attachments/70222123/Patient%20Dataset%20Results%20QIN%20PET%20CT%20WG%20Patient%20Dataset%20Feature%20Values_Table3_supporting_data.xlsx?api=v2 |
---|
|
|
| | Harmonized GLCM Entropy Results (xlsx, 17 kb) | Tcia button generator |
---|
url | https://wiki.cancerimagingarchive.net/download/attachments/70222123/Harmonized%20GLCM%20Entropy%20Results%20QIN%20PET%20CT%20WG%20Patient%20Dataset%20Feature%20Values_Table4_supporting_data.xlsx?api=v2 |
---|
|
|
| |
Collections Used in this Third Party Analysis Below is a list of the Collections used in these analyses: Source Data Type | Download | License |
---|
Corresponding Original Images and Segmentations CT images from LIDC-IDRI and DRO-Toolkit (DICOM, 2.0 GB) | Tcia button generator |
---|
url | https://wiki.cancerimagingarchive.net/download/attachments/70222123/Standardization%20in%20Quantitative%20Imaging%20DICOM%20CTs%203%20Subjects%20DRO%20Toolkit%2010%20Subjects%20QINRadiomic-Feature-Standards-DICOM%20CTs%203%20Subjects%20DRO%20Toolkit%2010%20Subjects%20QIN.tcia?version=1&modificationDate=1588698608471&api=v2 |
---|
| Download |
Tcia button generator |
---|
label | Search |
---|
url | https://nbia.cancerimagingarchive.net/nbia-search/?ImageModalityCriteria=CT&MinNumberOfStudiesCriteria=1&PatientCriteria=Phantom-100.0-1.0-1.0-1.0-9.0-0.0-100.0-10.0-0.0-0.0,Phantom-100.0-1.0-1.0-1.0-9.0-0.0-100.0-10.0-50.0-0.0,Phantom-100.0-1.0-1.0-1.0-9.0-0.2-100.0-10.0-0.0-0.0,LIDC-IDRI-0314,LIDC-IDRI-0325,LIDC-IDRI-0580,LIDC-IDRI-0766,LIDC-IDRI-0771,LIDC-IDRI-0811,LIDC-IDRI-0905,LIDC-IDRI-0963,LIDC-IDRI-0965,LIDC-IDRI-1012 |
---|
| Search |
(Requires NBIA Data Retriever.) | | Corresponding Original second-generation SEG images from QIN-LungCT-Seg Segmentations (DICOM, 123 MB) | Tcia button generator |
---|
url | https://wiki.cancerimagingarchive.net/download/attachments/70222123/Standardization%20in%20Quatitative%20Imaging%20DICOM%20Segs%203%20Subjects%20DRO%20Toolkit%2010%20Subjects%20QINRadiomic-Feature-Standards-DICOM%20Segs%203%20Subjects%20DRO%20Toolkit%2010%20Subjects%20QIN.tcia?api=v2 |
---|
| Download |
Tcia button generator |
---|
label | Search |
---|
url | https://nbia.cancerimagingarchive.net/nbia-search/?ImageModalityCriteria=SEG&MinNumberOfStudiesCriteria=1&PatientCriteria=Phantom-100.0-1.0-1.0-1.0-9.0-0.0-100.0-10.0-0.0-0.0,Phantom-100.0-1.0-1.0-1.0-9.0-0.0-100.0-10.0-50.0-0.0,Phantom-100.0-1.0-1.0-1.0-9.0-0.2-100.0-10.0-0.0-0.0,LIDC-IDRI-0314,LIDC-IDRI-0325,LIDC-IDRI-0580,LIDC-IDRI-0766,LIDC-IDRI-0771,LIDC-IDRI-0811,LIDC-IDRI-0905,LIDC-IDRI-0963,LIDC-IDRI-0965,LIDC-IDRI-1012 |
---|
| Search |
(Requires NBIA Data Retriever.)
| |
|
Localtab |
---|
title | Detailed Description |
---|
| Detailed Description
DICOM Image Statistics |
|
---|
Modalities | CT, SEG | Number of Patients | 13 | Number of Studies | 13 | Number of Series | 26 | Number of Images | 3,867 | Images Size (GB) | 2 GB |
There are three datasets provided – two image datasets and one dataset consisting of four excel spreadsheets containing feature values. - The first image dataset is a set of three Digital Reference Objects (DROs) used in the project, which are: (a) a sphere with uniform intensity, (b) a sphere with intensity variation (c) a nonspherical (but mathematically defined) object with uniform intensity. These DROs were created by the team at Stanford University and are described in (Jaggi A, Mattonen SA, McNitt-Gray M, Napel S. Stanford DRO Toolkit: digital reference objects for standardization of radiomic features. Tomography. 2019;6:–.) and are a subset of the DROs described in Stanford DRO Toolkit: Digital Reference Objects for Standardization of Radiomic Features. Each DRO is represented in both DICOM and NIfTI format and the VOI was provided in each format as well (DICOM Segmentation Object (DSO) as well as NIfTI segmentation boundary).
- The second image dataset is the set of 10 patient CT scans, originating from the LIDC-IDRI dataset, that were used in the QIN multi-site collection of Lung CT data with Nodule Segmentations project ( https://doi.org/10.7937/K9/TCIA.2015.1BUVFJR7 ). In that QIN study, a single lesion from each case was identified for analysis and then nine VOIs were generated using three repeat runs of three segmentation algorithms (one from each of three academic institutions) on each lesion. To eliminate one source of variability in our project, only one of the VOIs previously created for each lesion was identified and all sites used that same VOI definition. The specific VOI chosen for each lesion was the first run of the first algorithm (algorithm 1, run 1). DICOM images were provided for each dataset and the VOI was provided in both DICOM Segmentation Object (DSO) and NIfTI segmentation formats.
- The third dataset is a collection of four excel spreadsheets, each of which contains detailed information corresponding to each of the four tables in the publication. For example, the raw feature values and the summary tables for Tables 2,3 and 4 reported in the publication cited (https://doi.org/10.18383/j.tom.2019.00031). These tables are:
Software Package details : This table contains detailed information about the software packages used in the study (and listed in Table 1 in the publication) including version number and any parameters specified in the calculation of the features reported. DRO results : This contains the original feature values obtained for each software package for each DRO as well as the table summarizing results across software packages (Table 2 in the publication) . Patient Dataset results: This contains the original feature values for each software package for each patient dataset (1 lesion per case) as well as the table summarizing results across software packages and patient datasets (Table 3 in the publication). Harmonized GLCM Entropy Results : This contains the values for the “Harmonized” GLCM Entropy feature for each patient dataset and each software package as well as the summary across software packages (Table 4 in the publication). Patient IDs for the 3 DROs from (https://doi.org/10.7937/t062-8262) Phantom-100.0-1.0-1.0-1.0-9.0-0.0-100.0-10.0-0.0-0.0 Phantom-100.0-1.0-1.0-1.0-9.0-0.0-100.0-10.0-50.0-0.0 Phantom-100.0-1.0-1.0-1.0-9.0-0.2-100.0-10.0-0.0-0.0 Patient IDs for the 10 LIDC-IDRI subjects (https://doi.org/10.7937/K9/TCIA.2015.LO9QL9SX) LIDC-IDRI-0314 LIDC-IDRI-0325 LIDC-IDRI-0580 LIDC-IDRI-0766 LIDC-IDRI-0771 LIDC-IDRI-0811 LIDC-IDRI-0905 LIDC-IDRI-0963 LIDC-IDRI-0965 LIDC-IDRI-1012 Additional options for download:
DRO Data (3 subjects) | Download all or Query/Filter |
---|
Image Data (DICOM, 452.0 MB) CT only | Tcia button generator |
---|
url | https://wiki.cancerimagingarchive.net/download/attachments/70222123/DRO%20Toolkit-3%20Subjects-DICOM-CT%20Image%20Data%20TCIA%20Manifest.tcia?api=v2 |
---|
| Download |
Tcia button generator |
---|
label | Search |
---|
url | https://nbia.cancerimagingarchive.net/nbia-search/?ImageModalityCriteria=CT&MinNumberOfStudiesCriteria=1&PatientCriteria=Phantom-100.0-1.0-1.0-1.0-9.0-0.0-100.0-10.0-0.0-0.0,Phantom-100.0-1.0-1.0-1.0-9.0-0.0-100.0-10.0-50.0-0.0,Phantom-100.0-1.0-1.0-1.0-9.0-0.2-100.0-10.0-0.0-0.0&CollectionCriteria=DRO-Toolkit |
---|
| Search |
(Requires NBIA Data Retriever.) | Segmentation Data - DSO (DICOM, 29.0 MB) | Tcia button generator |
---|
url | https://wiki.cancerimagingarchive.net/download/attachments/70222123/DRO%20Toolkit-3%20Subjects-DICOM-Segmentation%20Data%20TCIA%20Manifest.tcia?api=v2 |
---|
| Download |
Tcia button generator |
---|
label | Search |
---|
url | https://nbia.cancerimagingarchive.net/nbia-search/?ImageModalityCriteria=SEG&MinNumberOfStudiesCriteria=1&PatientCriteria=Phantom-100.0-1.0-1.0-1.0-9.0-0.0-100.0-10.0-0.0-0.0,Phantom-100.0-1.0-1.0-1.0-9.0-0.0-100.0-10.0-50.0-0.0,Phantom-100.0-1.0-1.0-1.0-9.0-0.2-100.0-10.0-0.0-0.0&CollectionCriteria=DRO-Toolkit |
---|
| Search |
(Requires NBIA Data Retriever.) | Segmentation Data - (NIfTI, zip, 926 KB) |
Tcia button generator |
---|
url | https://wiki.cancerimagingarchive.net/download/attachments/70222123/DRO%20Toolkit-3%20Subjects-SEG%20Images%20NIfTI%20.zip?api=v2 |
---|
| Download |
|
Patient Datasets (10 subjects) | Download all or Query/Filter |
---|
Image Data (DICOM, 1.0 GB) CT only |
Tcia button generator |
---|
url | https://wiki.cancerimagingarchive.net/download/attachments/70222123/LIDC-IDRI-10%20Subjects-DICOM%20CT%20Image%20Data%20TCIA%20manifest.tcia?api=v2 |
---|
| Download |
Tcia button generator |
---|
label | Search |
---|
url | https://nbia.cancerimagingarchive.net/nbia-search/?ImageModalityCriteria=CT&MinNumberOfStudiesCriteria=1&PatientCriteria=LIDC-IDRI-0314,LIDC-IDRI-0325,LIDC-IDRI-0580,LIDC-IDRI-0766,LIDC-IDRI-0771,LIDC-IDRI-0811,LIDC-IDRI-0905,LIDC-IDRI-0963,LIDC-IDRI-0965,LIDC-IDRI-1012&CollectionCriteria=LIDC-IDRI |
---|
| Search |
(Requires NBIA Data Retriever.) | Segmentation Data - (DICOM, 94 MB) |
Tcia button generator |
---|
url | https://wiki.cancerimagingarchive.net/download/attachments/70222123/LIDC-IDRI-10%20Subjects-DICOM%20SEG%20Image%20Data%20TCIA%20Manifest.tcia?api=v2 |
---|
| Download |
Tcia button generator |
---|
label | Search |
---|
url | https://nbia.cancerimagingarchive.net/nbia-search/?saved-cart=nbia-39001586554584246 |
---|
| Search |
(Requires NBIA Data Retriever.) | Segmentation Data - (NIfTI, zip, 21.0 KB) |
Tcia button generator |
---|
url | https://wiki.cancerimagingarchive.net/download/attachments/70222123/LIDC-IDRI-10%20Subjects-NIfTI-Patient_Image_Data_NIFTI_Segs.zip?api=v2 |
---|
| Download |
|
|
Localtab |
---|
title | Citations & Data Usage Policy |
---|
| Citations & Data Usage Policy Tcia limited license policy |
---|
Info |
---|
| McNitt-Gray, M.*, Napel, S.*, Jaggi, A., Mattonen, S.A., Hadjiiski, L., Muzi, M., Goldgof, D., Balagurunathan, Y., Pierce, L.A., Kinahan, P.E., Jones, E.F., Nguyen, A., Virkud, A., Chan, H-P., Emaminejad, N., Wahi-Anwar, M., Daly, M., Abdalah, M., Yang, H., Lu, L., Lv, W., Rahmim, A., Gastounioti, A., Pati, S., Bakas, S., Kontos, D., Zhao, B., Kalpathy-Cramer, J., Farahani, K. (2020). Data from the Standardization in Quantitative Imaging: A Multi-center Comparison of Radiomic Feature Values [Data set]. The Cancer Imaging Archive. DOI: https://doi.org/10.7937/tcia.2020.9era-gg29. |
Info |
---|
title | Publication Citation |
---|
| McNitt-Gray, M., Napel, S., Jaggi, A., Mattonen, S.A., Hadjiiski, L., Muzi, M., Goldgof, D., Balagurunathan, Y., Pierce, L.A., Kinahan, P.E., Jones, E.F., Nguyen, A., Virkud, A., Chan, H-P., Emaminejad, N., Wahi-Anwar, M., Daly, M., Abdalah, M., Yang, H., Lu, L., Lv, W., Rahmim, A., Gastounioti, A., Pati, S., Bakas, S., Kontos, D., Zhao, B., Kalpathy-Cramer, J., Farahani, K. (2020). Standardization in Quantitative Imaging: A Multi-center Comparison of Radiomic Feature Values, Tomography. https://doi.org/10.18383/j.tom.2019.00031. |
Info |
---|
| Clark, K., Vendt, B., Smith, K., Freymann, J., Kirby, J., Koppel, P., Moore, S., Phillips, S., Maffitt, D., Pringle, M., Tarbox, L., & Prior, F. (2013). The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository. Journal of Digital Imaging, 26(6), 1045–1057. https://doi.org/10.1007/s10278-013-9622-7 |
Info |
---|
title | Acknowledgement - Grant support |
---|
| - David Geffen School of Medicine at UCLA - U01CA181156
|
Info |
---|
title | Acknowledgement - Grant support |
---|
| - Stanford University School of Medicine – U01CA187947 and U24CA180927
|
Info |
---|
title | Acknowledgement - Grant support |
---|
| - University of Michigan - U01CA232931
|
Info |
---|
title | Acknowledgement - Grant support |
---|
| - University of Washington – R50CA211270, U01CA148131
|
Info |
---|
title | Acknowledgement - Grant support |
---|
| - University of South Florida - U24CA180927, U01CA200464
|
Info |
---|
title | Acknowledgement - Grant support |
---|
| - Moffitt Cancer Center – U01CA143062, U01CA200464, P30CA076292
|
Info |
---|
title | Acknowledgement - Grant support |
---|
| - UC San Francisco - U01CA225427
|
Info |
---|
title | Acknowledgement - Grant support |
---|
| - BC Cancer Research Centre - NSERC Discovery Grant: RGPIN-2019-06467
|
Info |
---|
title | Acknowledgement - Grant support |
---|
| - Columbia University- U01CA225431
|
Info |
---|
title | Acknowledgement - Grant support |
---|
| - Center for Biomedical Image Computing and Analytics at the University of Pennsylvania - U24CA189523, R01NS042645
|
Info |
---|
title | Acknowledgement - Grant support |
---|
| - Massachusetts General Hospital- U01CA154601, U24CA180927
|
In addition to the dataset citation above, please be sure to cite the following if you utilize these data in your research:
Other Publications Using This DataTCIA maintains a list of publications which leverage TCIA data. If you have a manuscript you'd like to add please contact TCIA's Helpdesk. |
Localtab |
---|
| Version 1 (Current): Updated 2020/06/09Data Type | Download all or Query/Filter |
---|
Corresponding Original | Images and Segmentations CT images from LIDC-IDRI and DRO-Toolkit (DICOM, 2.0 GB) | Tcia button generator |
---|
url | https://wiki.cancerimagingarchive.net/download/attachments/70222123/ |
---|
|
| Standardization%20in%20Quantitative%20Imaging%20DICOM%20CTs%203%20Subjects%20DRO%20Toolkit%2010%20Subjects%20QINRadiomic-Feature-Standards-DICOM%20CTs%203%20Subjects%20DRO%20Toolkit%2010%20Subjects%20QIN.tcia? |
|
| version=1&modificationDate=1588698608471& Tcia button generator |
---|
label | Search |
---|
url | https://nbia.cancerimagingarchive.net/nbia-search/?ImageModalityCriteria=CT&MinNumberOfStudiesCriteria=1&PatientCriteria=Phantom-100.0-1.0-1.0-1.0-9.0-0.0-100.0-10.0-0.0-0.0,Phantom-100.0-1.0-1.0-1.0-9.0-0.0-100.0-10.0-50.0-0.0,Phantom-100.0-1.0-1.0-1.0-9.0-0.2-100.0-10.0-0.0-0.0,LIDC-IDRI-0314,LIDC-IDRI-0325,LIDC-IDRI-0580,LIDC-IDRI-0766,LIDC-IDRI-0771,LIDC-IDRI-0811,LIDC-IDRI-0905,LIDC-IDRI-0963,LIDC-IDRI-0965,LIDC-IDRI-1012 |
---|
| Search |
( | Requires SEG segmentations Segmentations Seg (DICOM, 123 MB) | Tcia button generator |
---|
url | https://wiki.cancerimagingarchive.net/download/attachments/70222123/ |
---|
|
| Standardization%20in%20Quatitative%20Imaging%20DICOM%20Segs%203%20Subjects%20DRO%20Toolkit%2010%20Subjects%20QINRadiomic-Feature-Standards-DICOM%20Segs%203%20Subjects%20DRO%20Toolkit%2010%20Subjects%20QIN.tcia?api=v2 |
| Download |
Tcia button generator |
---|
label | Search |
---|
url | https://nbia.cancerimagingarchive.net/nbia-search/?ImageModalityCriteria=SEG&MinNumberOfStudiesCriteria=1&PatientCriteria=Phantom-100.0-1.0-1.0-1.0-9.0-0.0-100.0-10.0-0.0-0.0,Phantom-100.0-1.0-1.0-1.0-9.0-0.0-100.0-10.0-50.0-0.0,Phantom-100.0-1.0-1.0-1.0-9.0-0.2-100.0-10.0-0.0-0.0,LIDC-IDRI-0314,LIDC-IDRI-0325,LIDC-IDRI-0580,LIDC-IDRI-0766,LIDC-IDRI-0771,LIDC-IDRI-0811,LIDC-IDRI-0905,LIDC-IDRI-0963,LIDC-IDRI-0965,LIDC-IDRI-1012 |
---|
| Search |
( | Requires | Segmentation (NIfTI, zip, 4 MB) |
Tcia button generator |
---|
url | https://wiki.cancerimagingarchive.net/download/attachments/70222123/DRO%20Toolkit-3%20Subjects%20SEG%20and%20QIN%20multi-site%2010%20Subjects%20SEG%20NIfTI.zip?api=v2 |
---|
|
|
| Feature Variability Software Package details (xlsx) |
Tcia button generator |
---|
url | https://wiki.cancerimagingarchive.net/download/attachments/70222123/Table%201%20-%20Feature%20Variability%20Software%20Details_v2.xlsx?api=v2 |
---|
|
|
| DRO Results (xlsx) |
Tcia button generator |
---|
url | https://wiki.cancerimagingarchive.net/download/attachments/70222123/DRO%20Results%20Table%202%20QIN%20PET%20CT%20WG%20DRO%20Feature%20Values_Table2_supporting_data.xlsx?api=v2 |
---|
|
|
| Patient Dataset Results (xlsx) |
Tcia button generator |
---|
url | https://wiki.cancerimagingarchive.net/download/attachments/70222123/Patient%20Dataset%20Results%20QIN%20PET%20CT%20WG%20Patient%20Dataset%20Feature%20Values_Table3_supporting_data.xlsx?api=v2 |
---|
|
|
| Harmonized GLCM Entropy Results (xlsx) |
Tcia button generator |
---|
url | https://wiki.cancerimagingarchive.net/download/attachments/70222123/Harmonized%20GLCM%20Entropy%20Results%20QIN%20PET%20CT%20WG%20Patient%20Dataset%20Feature%20Values_Table4_supporting_data.xlsx?api=v2 |
---|
|
|
|
|
|