The following is relevant to analyzing the contrast dynamics of the BLISS pulse sequences. The pulse sequence parameters (repetition, echo time, etc.) can be extracted from the DICOM tags. The contrast aspects are as follows: The volume of Magnevist (Bayer) gadolinium contrast injected into the brachial vein is based on a rule of thumb which in ml's is 10% of the patient wright in POUNDS (NOT Kilograms as is recorded in the DICOM patient weight tag. Hence the injected volume for a 150 lb patient is 15 ml. (the DICOM tag entry on that patient will read "68"). The injection itself is 6 or 7 seconds, at a rate of 3cc per second. The first dynamic sequence is started 1 minute after the injection is started. Slice and pulse parameters are accessible in the DICOM tags.