Child pages
  • Task-Based Anthropomorphic CT Phantom for Radiomics Stability and Discriminatory Power Analyses (CT-Phantom4Radiomics)

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Redirect
delay5
locationhttps://www.cancerimagingarchive.net/collection/ct-phantom4radiomics/

Column
width70%

Summary

Excerpt

The aims of this dataset are to determine the stability of radiomics features against computed tomography (CT) parameter variations and to study their discriminative power concerning tissue classification using a 3D-printed CT phantom based on real patient data. A radiopaque 3D phantom was developed using real patient data and a potassium iodide solution paper-printing technique. Normal liver tissue and 3 lesion types (benign cyst, hemangioma, and metastasis) were manually annotated in the phantom. 238 CT series with 8 parameter variations of reconstruction algorithms, reconstruction kernels, slice thickness, and slice spacing are available.

In a preliminary study, we showed that the 8 CT parameter variation pairwise group comparisons had statistically significant differences on average in 78/86 radiomics features. On the other hand, 84% of the univariate radiomics feature tests had a successful and statistically significant differentiation of the 4 classes of liver tissue. We concluded that the differences in radiomics feature values obtained from different types of liver tissue are generally greater than the intraclass differences resulting from CT parameter variations.

The phantom was printed using the Phantom X solution detailed in the study, "Radiopaque Three-dimensional Printing: A Method to Create Realistic CT Phantoms". It relies on inkjet cartridges filled with potassium iodide solutions (600 mg/mL) with prints realized on plain paper (80 g/m2). Stacked paper sheets result in three-dimensional phantoms.  Because the printing process is very specific to the Phantom X company and no other printer can be used, we did not make the printer creation file publicly available.

This dataset can serve as a reference to assess both the discriminative power and stability of radiomics features with CT variations. In addition, it can be used to develop efficient data harmonization techniques to improve robustness of (deep) radiomics features and models.  Additional information and source code related to the project can be found at https://qa4iqi.github.io/.


...

Localtab Group


Localtab
activetrue
titleData Access

Data Access

Data TypeDownload all or Query/FilterLicense

Images & Segmentations (DICOM, 42.5 GB)


Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/140312704/CT-Phantom4Radiomicsv1.tcia?api=v2



Tcia button generator
labelSearch
urlhttps://nbia.cancerimagingarchive.net/nbia-search/?MinNumberOfStudiesCriteria=1&CollectionCriteria=CT-Phantom4Radiomics



(Download requires NBIA Data Retriever)

Tcia cc by 4

Click the Versions tab for more info about data releases.

Additional Resources for this Dataset

The following external resources have been made available by the data submitters.  These are not hosted or supported by TCIA, but may be useful to researchers utilizing this collection.

  • Additional information

    and source code related to the project

    about the QA4IQI project, as well as a link to a repository containing source code & instructions for running the radiomics feature extraction pipeline on the dataset can be found at

     

    https://qa4iqi.github.io

    /

    .


Localtab
titleDetailed Description

Detailed Description

Image Statistics

Radiology Image Statistics

Modalities

CT,SEG

Number of Patients

1

Number of Studies

238

Number of Series

476

Number of Images

78,452

Images Size (GB)42.5




Localtab
titleCitations & Data Usage Policy

Citations & Data Usage Policy

Tcia limited license policy


Info
titleData Citation

Schaer, R., Bach, M., Obmann, M., Flouris, K., Konukoglu, E., Stieltjes, B., Müller, H., Aberle, C., Jimenez del Toro, O. A., & Depeursinge, A. (2023). Task-Based Anthropomorphic CT Phantom for Radiomics Stability and Discriminatory Power Analyses (CT-Phantom4Radiomics) [Data set]. https://doi.org/10.7937/a1v1-rc66



Info
titlePublication Citation

Jimenez-del-Toro, O., Aberle, C., Bach, M., Schaer, R., Obmann, M. M., Flouris, K., Konukoglu, E., Stieltjes, B., Müller, H., & Depeursinge, A. (2021). The Discriminative Power and Stability of Radiomics Features With Computed Tomography Variations. In Investigative Radiology (Vol. 56, Issue 12, pp. 820–825). Ovid Technologies (Wolters Kluwer Health). https://doi.org/10.1097/rli.0000000000000795



Info
titleTCIA Citation

Clark, K., Vendt, B., Smith, K., Freymann, J., Kirby, J., Koppel, P., Moore, S., Phillips, S., Maffitt, D., Pringle, M., Tarbox, L., & Prior, F. (2013). The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository. In Journal of Digital Imaging (Vol. 26, Issue 6, pp. 1045–1057). Springer Science and Business Media LLC.https://doi.org/10.1007/s10278-013-9622-7

Other Publications Using This Data

The following publications are recommended by the data submitters that may be useful to researchers utilizing this collection:

  • Bach, M., Aberle, C., Depeursinge, A., Jimenez‐del‐Toro, O., Schaer, R., Flouris, K., Konukoglu, E., Müller, H., Stieltjes, B., & Obmann, M. M. (2023). 3D‐printed iodine‐ink CT phantom for radiomics feature extraction ‐ advantages and challenges. In Medical Physics. Wiley. https://doi.org/10.1002/mp.16373


TCIA maintains a list of publications which leverage TCIA data. If you have a manuscript you'd like to add please contact TCIA's Helpdesk.



Localtab
titleVersions

Version 1 (Current): Updated 2023/08/23

Data TypeDownload all or Query/FilterLicense

Images & Segmentations (DICOM, 42.5 GB)


Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/140312704/CT-Phantom4Radiomicsv1.tcia?api=v2



Tcia button generator
labelSearch
urlhttps://nbia.cancerimagingarchive.net/nbia-search/?MinNumberOfStudiesCriteria=1&CollectionCriteria=CT-Phantom4Radiomics



(Download requires NBIA Data Retriever)

Tcia cc by 4




...