Child pages
  • Imaging characterization of a metastatic patient derived model of adenocarcinoma pancreas: (PDMR-521955-158-R4)

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Summary

Redirect
delay5
locationhttps://www.cancerimagingarchive.net/collection/pdmr-521955-158-r4/

Excerpt

Pre-clinical animal models of spontaneous metastatic cancer are infrequent; the few that exist are exist are resource intensive because determination of the presence of metastatic disease,  metastatic metastatic burden, and response to therapy normally require multiple timed cohorts with animal sacrifice and extensive pathological extensive pathological examination. We identified and characterized a patient derived xenograft model xenograft model with metastatic potential, adenocarcinoma pancreas xenograft 521955-158-R4. In this study we performed a detailed imaging detailed imaging characterization (workflow below) of this model, which develops spontaneous lung metastases, details are provided in the attached standard operating procedures. Tumors in half of the mice were resected in the range 200-300 cmmm3 size; tumors in the other half were allowed to grow until it was necessary to euthanize them because of tumor size.

Image RemovedImage Added

The imaging characteristics of this model (PDMR-521955-158-R4), which is available from the National Cancer Institute Patient-Derived Models Repository (https://pdmr.cancer.gov/), is highly favorable for preclinical research studies of metastatic disease when used in conjunction with non-contrast T2 weighted MRI.

Results: Adenocarcinoma pancreas (PDMR-521955-158-R4)

Table 1: Penetrance and location of pathological confirmed metastatic lesion(s).

# animals in Group

# animals that displayed metastasis in MRI and confirmed by Pathology

Pathology confirmation of MRI (primary imaging site)

Other confirmed Location (s)

Mouse ID: MRI with pathology confirmation of metastasis


10 (non-resected)

4

(5 mice were EU due to xenograft size prior to observation of metastases)

Lung

Lung

2163, 2169, 2171, 2179


10 (resected)

7

Lung

Lung (70%)

                         Para


Para-vertebral muscle (50%)
Nodal disease (10%)

2160, 2161, 2164, 2170, 2172, 2176, 2178


Percent penetrance with respect to the average time-to-metastasis for non-resected (time from implant: 10.7 ± 1.8 weeks) and resected (time from tumor resection: 5.3 ± 1.1 weeks) cohorts.


PET/CT Characterization of the primary tumor:  Baseline PET (SOP attached) were performed when tumor reached an approximate 200 mm3.   Average SUVmax values (n=6) were calculated; [18F]FDG: 2.3 ± 0.8 and [18F]FLT: 2.4 ± 0.4.

Conclusion:

Good metastatic model with 40% penetrance un-resected and 70% with planned early resection.  Metastases are well observed on T2 MRI imaging allowing non-invasive evaluation in treatment trials.


Acknowledgements

We would like to acknowledge the individuals and institutions that have provided data for this collection:

  • Frederick National Laboratory for Cancer Research – Special Thanks to Joseph D. Kalen, PhD, Lilia V. Ileva, MS, Lisa A Riffle, Nimit L Patel, MS, Keita Saito, PhD, Yvonne Evrard, PhD, Elijah Edmondson, DVM, PhD, Justin Smith, Simone Difilippantonio, PhD, Chelsea Sanders, Ulrike Wagner, Yanling Liu, PhD, John B. Freymann, and Justin Kirby.

  • Division of Cancer Therapeutics and Diagnosis/National Cancer Institute - James L. Tatum, MD, Paula M Jacobs, PhD, Melinda G. Hollingshead, DVM, and James H. Doroshow, MD

  • PixelMed Publishing – Special Thanks to David A. Clunie, MD

  • University of Arkansas for Medical Sciences – Special Thanks to Kirk E. Smith

  • This project has been funded in whole or in part with Federal funds from the National Cancer Institution, National Institutes of Health, under Contract No. Number HHSN261200800001E. The content of this publication does not necessarily reflect the views or policies of the Department of Health and Human Services, nor does mention of trade names, commercial products, or organizations imply endorsement by the U.S. Government.
Localtab Group


tcia-button-generator
Localtab
activetrue
titleData Access

Data Access

Data TypeDownload all or Query/FilterLicense

Images (DICOM,

XX

2.

X

8 GB)


Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/127665355/PDMR-521955-158-R4.tcia?api=v2



Tcia button generator
labelSearch
urlhttps://nbia.cancerimagingarchive.net/nbia-search/?MinNumberOfStudiesCriteria=1&CollectionCriteria=PDMR-521955-158-R4



(Download requires NBIA Data Retriever)

Tcia cc by 4

PDMR Patient Specimen (external)

Tcia cc by 4

Standard Operating Procedure 50101: MRI T2 Weighted Non-Contrast Protocol:

 Single

Single Mouse Pulmonary Gated and Multi-Mouse Non-Gated (pdf, 141 kB)


Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/127665355/SOP50101_MRI%20T2%20Weighted%20Non-Contrast%20Protocol_Single%20Mouse%20Pulmonary%20Gated%20and%20Multi-Mouse%20Non-Gated.pdf?api=v2

SOP50101_MRI T2 Weighted Non-Contrast Protocol

_

Tcia cc by 4

Standard Operating Procedure 50102: Positron Emission Tomography (PET) imaging protocol (pdf, 165 kB)



Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/127665355/SOP50102_Positron%20Emission%20Tomography%20%28PET%29%20imaging%20protocol.pdf?api=v2

SOP50102_Positron Emission Tomography (PET) imaging protocol.pdf


Tcia cc by 4

Click the Versions tab for more info about data releases.

Pdmr additional resources

The NCI Cancer Research Data Commons (CRDC) provides access to additional data and a cloud-based data science infrastructure that connects data sets with analytics tools to allow users to share, integrate, analyze, and visualize cancer research data.


Localtab
titleDetailed Description

Detailed Description

Image Statistics

Radiology Image StatisticsPathology Image Statistics

Modalities

MR,SR

Number of Patients

20

Number of Studies

142

Number of Series

264

Number of Images

4608

Images Size (GB)2.8




Localtab
titleCitations & Data Usage Policy

Citations & Data Usage Policy

Tcia limited license policy

Info
titleData Citation

DOI goes here. Create using Datacite with information from Collection Approval form

Info
titlePublication Citation

We ask on the proposal form if they have ONE traditional publication they'd like users to cite.

Info
titleAcknowledgement

This project has been funded in whole or in part with Federal funds from the National Cancer Institution, National Institutes of Health, under Contract No. HHSN261200800001E. The content of this publication does not necessarily reflect the views or policies of the Department of Health and Human Services, nor does mention of trade names, commercial products, or organizations imply endorsement by the U.S. Government.Tatum, J., Kalen, J., Jacobs, P., Ileva, lilia, Riffle, L., Keita, S., Patel, N., Sanders, C., James, A., Difilippantonio, S., Thang, L., Hollingshead, M., Evrard, Y., Edmondson, E., Clunie, D., Liu, Y., Suloway, C., Smith, K., Wagner, U., Freymann, J. B., Kirby, J., Doroshow, J. (2022).Imaging characterization of a metastatic patient derived model of adenocarcinoma pancreas: (PDMR-521955-158-R4) (Version 1) [Data set]. The Cancer Imaging Archive. https://doi.org/10.7937/q37d-vh79 


Info
titleTCIA Citation

Clark K, Vendt B, Smith K, Freymann J, Kirby J, Koppel P, Moore S, Phillips S, Maffitt D, Pringle M, Tarbox L, Prior F. The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository, Journal of Digital Imaging, Volume 26, Number 6, December, 2013, pp 1045-1057. DOI: 10.1007/s10278-013-9622-7

Other Publications Using This Data

TCIA maintains a list of publications which leverage TCIA data. If you have a manuscript you'd like to add please contact the TCIA Helpdesk.


Localtab
titleVersions

Version

X

1 (Current): Updated

yyyy

2022/

mm

08/

dd

17

Data TypeDownload all or Query/Filter
License

Image (DICOM,

XX

2.

X

8 GB)



Tcia button generator



Tcia button generator
labelSearch


(Download requires the NBIA Data Retriever

)

Tcia cc by 4

PDMR Patient Specimen (external

)

Tcia button generatortcia-cc-by-4

Standard Operating Procedure 50101: MRI T2 Weighted Non-Contrast Protocol: Single Mouse Pulmonary Gated and Multi-Mouse Non-Gated


Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/127665355/SOP50101_MRI%20T2%20Weighted%20Non-Contrast%20Protocol_Single%20Mouse%20Pulmonary%20Gated%20and%20Multi-Mouse%20Non-Gated.pdf?api=v2
tcia-cc-by-4



Standard Operating Procedure 50102: Positron Emission Tomography (PET) imaging protocol






Tcia button generator
url
file
https://
/C:/Users/campbrittney/Downloads/SOP50102_Positron%20Emission%20Tomography%20(PET)%20imaging%20protocol.pdf
<< One or two sentences about what you changed since last version.  No note required for version 1. >> 
wiki.cancerimagingarchive.net/download/attachments/127665355/SOP50102_Positron%20Emission%20Tomography%20%28PET%29%20imaging%20protocol.pdf?api=v2