Child pages
  • Synthetic and Phantom MR Images for Determining Deformable Image Registration Accuracy (MRI-DIR)

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Summary

...

This data collection consists of

The full title can be “Radiomic Biomarkers in Oropharyngeal Carcinoma”.

oropharynx squamous cell carcinoma

This will be sufficient for the 2 manuscripts that use the data to be shared on TCIA.

Radiomic Biomarkers to Refine Risk Models for Distant Metastasis in Oropharyngeal Carcinoma

...

Redirect
delay5
locationhttps://www.

...

cancerimagingarchive.

...

net/

...

collection/

...

Purpose: Distant metastasis (DM) is the main cause of death for patients with human papillomavirus (HPV)-related oropharyngeal cancers (OPC); yet there are few reliable predictors of DM in this disease. The role of quantitative imaging (i.e. radiomic) analysis was examined to determine whether there are primary tumor features discernible on imaging studies that associate with a higher risk of developing DM.

Methods: Radiotherapy planning CT scans were retrieved for all non-metastatic p16-positive OPC patients treated with radiotherapy or chemoradiotherapy at a single institution between 2005 and 2010. Radiomic biomarkers were derived from each gross tumor volume (GTV). Biomarkers included four representative radiomic features from tumor first order statistics, shape, texture, and wavelet groups as well as a combined four-feature signature. Univariable Cox proportional hazards models for DM risk were identified. Discriminative performance of prognostic univariable and multivariable models was compared using the concordance index (C-index). Subgroup analyses were performed.

Results: There were 300 HPV-related OPC patients who were eligible for the analysis. A total of 36 DM events occurred within a median follow-up of five years. On univariable analysis, top results included the four representative radiomic features (p<0.001), the radiomic signature (p<0.001), tumor stage (p<0.001), tumor diameter (p<0.001), and tumor volume (p<0.001). C-indices of the radiomic features (0.670-0.686), radiomic signature (0.670), stage (0.633), and tumor size metrics (0.653-0.674) demonstrated moderate discrimination of DM risk. Combined clinical-radiomic models yielded significantly improved performance (0.701-0.714; p<0.05). In subgroup analyses, the radiomic biomarkers consistently stratified patients for DM risk, particularly for those cohorts with greater risks (0.663-0.796), such as patients with stage III disease.

Conclusions: Radiomic biomarkers appear to classify DM risk for patients with non-metastatic HPV-related OPC. Radiomic biomarkers could be used either alone or with other clinical characteristics in assignment of DM risk in future HPV-related OPC clinical trials.

Oropharynx cancer is increasing in frequency in North America. More refined risk stratification and treatment personalization strategies are needed to improve cure rates and limit toxicities. Radomic features have shown promise for prognostication in oropharynx cancer based on datasets including hundreds of patients. Clinical outcomes data for oropharynx cancer patients treated at Princess Margaret Cancer Centre is of the highest quality, collected prospectively at the point of care. This data has resulted in the recent AJCC/UICC 8th edition staging system for oropharynx cancer (first published by O'Sullivan et al. in Lancet Oncology, 2016 [PMID 26936027]). By making publicly available the published data from our institution, which has now been published twice (see next question), we will empower researchers to perform meta-analysis and validation exercises of prognostic radiomic models. Ultimately this will lead to more robust models and bring us closer to clinical implementation and impact for our patients.

...

mri-dir/

Excerpt

Two sets of images were created to evaluate deformable image registration accuracy. The first set contains CT, T1-, and T2-weighted images from a porcine phantom. The phantom was implanted with ten 0.35 mm gold markers and then immobilized in a plastic container with movable dividers. The porcine phantom was compressed in 4 different ways and images were acquired in each position. The markers were visible on the CT scans but not the MR scans due to the selected voxel size. Therefore, the markers do not interfere with the registration between MR images and the marker locations can be obtained from the CT images to determine accuracy. The second set of images are synthetic images derived from 28 head and neck squamous cell carcinoma patients who had pre-, mid-, and post-radiotherapy treatment MR scans. From these patients, inter- and intra-patient models were created. Four synthetic pre-treatment images were created by using the inter-patient model on a selected template patient. Four synthetic post-treatment images were created for each synthetic pre-treatment image using the intra-patient model.



For scientific inquiries about this dataset, please contact: Dr. Scott Bratman Scott.Bratman@rmp.uhn.ca

 

Localtab Group


Localtab
activetrue
titleData Access

Data Access

 Choosing the Download option will provide you with a file to launch the TCIA Download Manager to download the entire collection. If you want to browse or filter the data to select only specific scans/studies please use the Search option.

Tcia head license access

Data TypeDownload all or Query/Filter
Images

Images and Radiation Therapy Structures (DICOM,
XX GB)

Image Removed Image Removed

Clinical (e.g. patient demographics, outcomes)

Image Removed

Detailed clinical, genomic, and expression array data
1.4 GB)


Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/37224702/MRI-DIR-06-30-2018-doiJNLP-1UmgA3nc.tcia?version=1&modificationDate=1534787062144&api=v2



Tcia button generator
labelSearch
urlhttps://www.cancerimagingarchive.net/nbia-search/?CollectionCriteria=MRI-DIR




(Download requires the NBIA Data Retriever)

Tcia restricted license

Deformation Vector Fields (MATLAB, 1.7 GB)


Tcia button generator
labelSearch
urlhttps://app.box.com/s/w9d6njvgf5z68waveq47c0xfsf9ffw6a



Tcia cc by 3

Image Removed

Click the Versions tab for more info about data releases.


Localtab
titleDetailed Description

Detailed Description

Modalities

Collection Statistics

 


Modalities

CT, MR, RTSTRUCT, Matlab

Number of Patients

9

Number of Studies

25

Number of Series

61

Number of Images

3596

Image Size (GB)

Supporting Documentation

In addition to the DICOM images in TCIA,
1.4



Localtab
titleCitations & Data Usage Policy

Citations & Data Usage Policy 

 This collection is freely available to browse, download, and use for commercial, scientific and educational purposes as outlined in the Creative Commons Attribution 3.0 Unported License.  See TCIA's Data Usage Policies and Restrictions for additional details. Questions may be directed to help@cancerimagingarchive.net.

Please be sure to include the following citations in your work if you use this data set:

Tcia limited license policy

Info
titleData Citation

Ger, R.B., Yang, J., Ding, Y., Jacobsen, M.C., Cardenas, C.E., Fuller, C.D., Howell, R.M., Li, H., Stafford, R. J., Zhou, S., & Court, L. (2018). Data from Synthetic and Phantom MR Images for Determining Deformable Image Registration Accuracy (MRI-DIR) (Version 1)

Info
titleData Citation

 Authors (2018). Data from Radiomic Biomarkers to Refine Risk Models for Distant Metastasis in Oropharyngeal Carcinoma. The Cancer Imaging Archive. httpDOI: https://dx.doi.org link coming soon/10.7937/K9/TCIA.2018.3f08iejt


Info
titlePublication Citation

Coming soonGer, R. B., Yang, J., Ding, Y., Jacobsen, M. C., Cardenas, C. E., Fuller, C. D., Howell, R. M., Li, H., Stafford, R. J., Zhou, S., & Court, L. E. (2018). Synthetic head and neck and phantom images for determining deformable image registration accuracy in magnetic resonance imaging. In Medical Physics (Vol. 45, Issue 9, pp. 4315–4321). Wiley. https://doi.org/10.1002/mp.13090


Info
titleTCIA Citation

Clark, K., Vendt, B., Smith, K., Freymann, J., Kirby, J., Koppel, P., Moore, S., Phillips, S., Maffitt, D., Pringle, M., Tarbox, L., & Prior, F.  (2013). The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository, . In Journal of Digital Imaging , Volume (Vol. 26, Number Issue 6, December, 2013, pp 1045-1057. (paper)1045–1057). Springer Science and Business Media LLC. https://doi.org/10.1007/s10278-013-9622-7 PMCID: PMC3824915

Other Publications Using This Data

TCIA maintains a list of publications which leverage our data. At this time we are not aware of any publications based on this data. If you have a publication you'd like to add please contact the TCIA's Helpdesk. 



Localtab
titleVersions

Version 1 (Current): Updated 2018/

xx

06/

xx

30

Data TypeDownload all or Query/Filter
Images (DICOM,  XXX1.X GB)

Image Removed Image Removed

Summary clinical data

Image Removed

Detailed clinical, genomic, and expression array data

Image Removed

 

4 GB)


Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/37224702/MRI-DIR-06-30-2018-doiJNLP-1UmgA3nc.jnlp?version=1&modificationDate=1530371992607&api=v2



Tcia button generator
labelSearch
urlhttps://www.cancerimagingarchive.net/nbia-search/?CollectionCriteria=MRI-DIR



(Download requires the NBIA Data Retriever)

Deformation Vector Fields (MATLAB)


Tcia button generator
labelSearch
urlhttps://app.box.com/s/w9d6njvgf5z68waveq47c0xfsf9ffw6a