Child pages
  • Low Dose CT Image and Projection Data (LDCT-and-Projection-data)

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...


Localtab Group


Localtab
activetrue
titleData Access

Data Access

Click the  Download button to save a ".tcia" manifest file to your computer, which you must open with the NBIA Data Retriever . Click the Search button to open our Data Portal, where you can browse the data collection and/or download a subset of its contents.


Data TypeDownload all or Query/Filter
Images (DICOM, 952 GB)

 

Download button not active

(Requires NBIA Data Retriever .)

Images (DICOM, 2.0 GB) - Phantom Object Only

 

DICOM-CT-PD User Manual Version 3 (.pdf)

Matlab DICOM-CTPD data dictionary (.txt)

Matlab DICOM-CTPD reader script (.txt)

Clinical Data (CSV, zip)

Click the Versions tab for more info about data releases.


Important information about the GE patient cases (included in Version 1, not currently available).
 
An incorrect value was found in the RescaleIntercept DICOM tag (0028,1052) in the GE data. Additionally, we have been asked by users to determine and add PhotonStatistics values to DICOM tag (7033,1065). Hence, access to the GE data (149 cases) has been temporarily suspended while we address these issues.

  • If you have already downloaded the GE data, you will want to download the updated data when it is again available.
  • The GE data are readily recognized, as they have only 3 series per patient case (Siemens data have 4).
  • The GE data can also be identified using the DICOM tag (0008,0070).
  • If you have already started a project with the GE data, please contact the Mayo team to discuss the issues in greater detail to discern if they impact your work. Please send your inquiry to CTCIC@mayo.edu and the team will follow up with you.

We sincerely apologize for this inconvenience.

Click the Versions tab for more info about data releases
  • .




Localtab
titleDetailed Description

Detailed Description

Image Statistics


Modalities

CT

Number of Participants

151

Number of Studies

301

Number of Series

601

Number of Images

10,112,591

Images Size (TB)1.23


For each patient CT scan, three types of data are provided: DICOM-CT-PD projection data, DICOM image data, and Excel clinical data reports. CT projection data are provided for both full and simulated lower dose levels and CT image data reconstructed using the commercial CT system are provided for the full dose projection data. For patients scanned on the SOMATOM Definition Flash CT scanner from Siemens Healthcare, CT image data reconstructed using the commercial CT system are also provided for the lower dose projection data. All CT images were reconstructed using a filtered back projection method. Several instructional documents are provided to help users extract needed information from the DICOM-CT-PD files, including a dictionary file for the DICOM-CT-PD format, a DICOM-CT-PD reader, and a user manual.

This collection comprises 99 head scans (labeled N for neuro), 100 chest scans (labeled C for chest), and 100 abdomen scans (labeled L for liver). Fifty cases for each scan type are from a SOMATOM Definition Flash CT scanner (Siemens Healthcare, Forchheim, Germany). Forty-nine head cases, 50 chest cases, and 50 abdomen cases are from a Lightspeed VCT CT scanner (GE Healthcare, Waukesha, WI). Together, these data will greatly facilitate the development and validation of new CT reconstruction and/or denoising algorithms, including those associated with machine learning or artificial intelligence.

Acquisition protocol

All CT scans were acquired at routine dose levels for the practice at which they were obtained using standard-clinical protocols for the anatomical region of interest. Each clinical case was processed to include a second projection dataset at a simulated lower dose level.  Head and abdomen cases are provided at 25% of the routine dose and chest cases are provided at 10% of the routine dose.

1Additional information regarding the CT projection data format: Chen B, Duan X, Yu Z, Leng S, Yu L, McCollough CH. Technical Note: Development and validation of an open data format for CT projection data. Med Phys. 2015;42(12):6964. (doi: https://doi.org/10.1118/1.4935406.)


Localtab
titleCitations & Data Usage Policy

Citations & Data Usage Policy

Public collection license

Info
titleData Citation

McCollough, C.H., Chen, B., Holmes, D., III, Duan, X., Yu, Z., Yu, L., Leng, S., Fletcher, J. (2020). Data from Low Dose CT Image and Projection Data [Data set]. The Cancer Imaging Archive.  https://doi.org/10.7937/9npb-2637


Info
titleGrant Citation

Presentations and publications shall acknowledge grants EB017095 and EB017185 (Cynthia McCollough, PI) from the National Institute of Biomedical Imaging and Bioengineering.


Info
titleTCIA Citation

Clark K, Vendt B, Smith K, Freymann J, Kirby J, Koppel P, Moore S, Phillips S, Maffitt D, Pringle M, Tarbox L, Prior F. The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository, Journal of Digital Imaging, Volume 26, Number 6, December, 2013, pp 1045-1057. DOI: 10.1007/s10278-013-9622-7

Other Publications Using This Data

TCIA maintains a list of publications which leverage TCIA data. If you have a manuscript you'd like to add please contact the TCIA Helpdesk.




Localtab
titleVersions

Version 2 (Current): Updated 2020/08/11

Data TypeDownload all or Query/Filter
Images (DICOM, 952 GB)

Image Modified   Image Modified

Download button not active

(Requires NBIA Data Retriever .)

Images (DICOM, 2.0 GB)

Phantom Object Only

DICOM-CT-PD User Manual Version 3 (.pdf)


Image Modified

Matlab DICOM-CTPD data dictionary (.txt)

Matlab DICOM-CTPD reader script (.txt)
Clinical Data (CSV, zip)

Important information about the GE patient cases.
 
An incorrect value was found in the RescaleIntercept DICOM tag (0028,1052) in the GE data. Additionally, we have been asked by users to determine and add PhotonStatistics values to DICOM tag (7033,1065). Hence, access to the GE data (149 cases) has been temporarily suspended while we address these issues.
 

  • If you have already downloaded the GE data, you will want to download the updated data when it is again available.
  • The GE data are readily recognized, as they have only 3 series per patient case (Siemens data have 4).
  • The GE data can also be identified using the DICOM tag (0008,0070).
  • If you have already started a project with the GE data, please contact the Mayo team to discuss the issues in greater detail to discern if they impact your work. Please send your inquiry to CTCIC@mayo.edu and the team will follow up with you.

Version 1: Updated 2020/04/22

Data TypeDownload all or Query/Filter
Images (DICOM, 1.23 TB)

 

Download button not active

(Requires NBIA Data Retriever .)

Images (DICOM, 2.0 GB)

Phantom Object Only

 

DICOM-CT-PD User Manual Version 3 (.pdf)


Matlab DICOM-CTPD data dictionary (.txt)

Matlab DICOM-CTPD reader script (.txt)

Clinical Data (CSV, zip)






...