Child pages
  • Segmentation of Vestibular Schwannoma from Magnetic Resonance Imaging: An Annotated Multi-Center Routine Clinical Dataset (Vestibular-Schwannoma-MC-RC)

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 11 Next »

Summary

The Vestibular Schwannoma Multi-Center Routine Clinical (VS-MC-RC) dataset contains longitudinal MRI scans of 160 patients with a single sporadic Vestibular Schwannoma (VS) from 10 medical sites in the United Kingdom. For all patients either a T1-weighted or T2-weighted scan, or both, are available. The dataset provides binary segmentations of the VS for all scan sessions. The dataset comprises up to three time points for each patient resulting in a total of 428 timepoints and 487 3D-images. These timepoints represent the first, central, and last MRI exams that the patients underwent. Manual ground truth segmentations were obtained in an iterative process in which segmentations were: 1) produced or amended by a specialized company; and 2) reviewed by one of three trained radiologists; and 3) validated by an expert team. Using this dataset, researchers can develop and validate methods, for example, for automatic surveillance of Vestibular Schwannoma, which work robustly on images acquired at different hospitals.

Pre-processing

The MRI images are provided in DICOM format. All images were defaced using automatic affine registration or manual landmark registration with BRAINSFit and the template and face mask provided in pydeface. Segmentations are provided in NIfTI format.

Comparison to VS-SEG dataset

Compared to the Vestibular-Schwannoma-SEG (VS-SEG) dataset which was acquired with a standardized protocol for radiation treatment planning on a single scanner at a single site, the VS-MC-RC dataset aims to capture the diversity of MRI scans encountered in a routine clinical setting; it contains a wide range of scan protocols and was acquired on multiple scanners by different manufacturers. In addition, the tumour manifestation in scans of this dataset is more diverse because it includes tumours at early stages and post-operative tumour residuals rather than only tumours specifically selected for radiation therapy.

Patient overlap with VS-SEG dataset

Fifty-eight patients of the VS-MC-RC dataset were previously included in the VS-SEG dataset. These patients have a Patient ID that begins with “VS-SEG- “. Patient IDs of patients that are not part of the VS-SEG dataset begin with “VS-MC-RC-”. Please note that for most patients that are part of both datasets, the timepoints and MRI series included in one dataset are different from those included in the other dataset. However, 8 series are included in both datasets. These series are listed in the CSV file below.

Acknowledgements

We would like to acknowledge the individuals and institutions that have provided data for this collection:

This work was supported by Wellcome Trust (203145Z/16/Z, 203148/Z/16/Z, WT106882), EPSRC (NS/A000050/1, NS/A000049/1) and MRC (MC/PC/180520) funding. Additional funding was provided by Medtronic. TV is also supported by a Medtronic/Royal Academy of Engineering Research Chair (RCSRF1819/7/34).

Data Access

Some data in this collection contains images that could potentially be used to reconstruct a human face. To safeguard the privacy of participants, users must sign and submit a TCIA Restricted License Agreement to help@cancerimagingarchive.net before accessing the data.


Data TypeDownload all or Query/FilterLicense

Images (DICOM, XX.X GB)


   

(Download requires NBIA Data Retriever)

Segmentations (NIfTI, zip) 
Mapping of series in Vestibular-Schwannoma-SEG dataset (csv)


Click the Versions tab for more info about data releases.



Detailed Description

Image Statistics

Radiology Image Statistics

Modalities

MR

Number of Patients

160

Number of Studies

428

Number of Series

487

Number of Images


Images Size (GB)



Citations & Data Usage Policy

Users must abide by the TCIA Data Usage Policy and Restrictions. Attribution should include references to the following citations:

Data Citation

Kujawa, A., Dorent, R., Wijethilake, N., Connor, S., Thomson, S., Ivory, M., Bradford, R., Kitchen, N., Bisdas, S., Ourselin, S., Vercauteren, T., Shapey, J. (2023). Segmentation of Vestibular Schwannoma from Magnetic Resonance Imaging: An Annotated Multi-Center Routine Clinical Dataset (Vestibular-Schwannoma-MC-RC) [Data set]. The Cancer Imaging Archive. https://doi.org/10.7937/hrzh-2n82 (draft doi, not resolvable).

Publication Citation


TCIA Citation

Clark, K., Vendt, B., Smith, K., Freymann, J., Kirby, J., Koppel, P., Moore, S., Phillips, S., Maffitt, D., Pringle, M., Tarbox, L., & Prior, F. (2013). The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository. In Journal of Digital Imaging (Vol. 26, Issue 6, pp. 1045–1057). Springer Science and Business Media LLC. https://doi.org/10.1007/s10278-013-9622-7

Other Publications Using This Data

TCIA maintains a list of publications which leverage TCIA data. If you have a manuscript you'd like to add please contact the TCIA Helpdesk.

Version 1 (Current): Updated 2023/mm/dd

Data TypeDownload all or Query/FilterLicense

Images (DICOM, XX.X GB)


    (Download requires the NBIA Data Retriever)

Segmentations (NIfTI, zip) 
Mapping of series in Vestibular-Schwannoma-SEG dataset (csv)




  • No labels