Summary

Excerpt

The RADCURE dataset was collected clinically for radiation therapy treatment planning and retrospectively reconstructed for quantitative imaging research.  

Acquisition and Validation Methods:  RADCURE RADCURE is comprised of data for 3,346 patients and contains computed tomography (CT) images with corresponding normal and non-normal tissue contours. CT scans were collected using systems from three different manufacturers. Standard clinical imaging protocols were followed, and contours were generated and reviewed at weekly quality assurance rounds. RADCURE imaging and structure set data was extracted from our institution’s radiation treatment planning and oncology systems using an in-house data mining and processing system. Furthermore, images are linked to clinical data for each patient and includes include demographic, clinical and treatment information based on the 7th edition TNM staging system. The median patient age is 63, with the final dataset including 80% males. Oropharyngeal cancer makes of up 50% of the population with larynx, nasopharynx, and hypopharynx cancer, comprising 25, 12, and 5% respectively. Median follow-up was 5 years with 60% of the patients alive at last follow-up.   

Data Format and Usage Notes: During extraction of images and contours from our institution’s radiation treatment planning and oncology systems, the data was converted to DICOM and RTSTRUCT formats, respectively. To improve the usability of the RTSTRUCT files, individual contour names were standardized for primary tumor volumes , and 29 organs-at-risk. Demographic, clinical, and treatment information is provided as a comma-separated values (csv) file. This dataset is a superset of the Radiomic Biomarkers in Oropharyngeal Carcinoma (OPC-Radiomics) dataset and fully encapsulates all previous data; this dataset replaces the OPC-Radiomics dataset. The RTSTRUCTs from OPC-Radiomics have been standardized to adhere to the TG-263 TG263 nomenclature. Age of 90 years or greater is considered PHI and set to 90 years to minimize impact to privacy. Both radiological and clinical metadata were offset by an undisclosed number of days for anonymization and should be noted for downstream analysis. The TG263-standardized RTSTRUCTs include only the GTVp (primary gross tumor volume) contours. Patients without corresponding GTVp contours will not have RTSTRUCTs.

Potential Applications: The availability of imaging, clinical, demographic and treatment data in RADCURE makes it a viable option for a variety of quantitative image analysis research initiatives. This includes the application of machine learning or artificial intelligence methods to expedite routine clinical practices, discover new non-invasive biomarkers, or develop prognostic models.  

Inclusion: The dataset used for this study consists of 3346 head and neck cancer CT image volumes collected from2005-2017 treated with definitive RT at the University Health Network (UHN) in Toronto, Canada

Acknowledgements

We would like to acknowledge the individuals and institutions that have provided data for this collection:

...

Localtab Group


Localtab
activetrue
titleData Access

Data Access

Tcia head license access

Data TypeDownload all or Query/FilterLicense

Images and Radiation Therapy Structures, full dataset (DICOM, 324 GB)


Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/70226325/RADCURE%20Phase%201%20release%20Jun%201%202023.tcia?api=v2



Tcia button generator
labelSearch
urlhttps://nbia.cancerimagingarchive.net/nbia-search/?MinNumberOfStudiesCriteria=1&CollectionCriteria=RADCURE



(Download requires the NBIA Data Retriever)

Tcia restricted license

Images and Radiation Therapy Structures, updated OPC-Radiomics (DICOM,

334 GB)Image RemovedImage Removed

57 GB)



Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/70226325/RADCURE%20OPC%20only%20Phase%201%20manifest%20Jun%201%202023.tcia?api=v2



Tcia button generator
labelSearch
urlhttps://nbia.cancerimagingarchive.net/nbia-search/?saved-cart=nbia-22801683744260516


(Download requires the NBIA Data Retriever)

Tcia restricted license

Clinical data (CSV, 452 kB)


Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/70226325/RADCURE_TCIA_Clinical%20June%2013%202023.xlsx?api=v2



Tcia cc by 4

Patient ID Mapping-RADCURE patient id to OPC-RADIOMICS patient id (CSV
)Image Removed
, 14 kB)


Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/70226325/RADCURE%20patient%20id%20to%20OPC-Radiomics%20patient%20id%20mapping.csv?api=v2



Tcia cc by 4

Click the Versions tab for more info about data releases.

Please contact help@cancerimagingarchive.net  with any questions regarding usage.


Localtab
titleDetailed Description

Detailed Description

Image Statistics


Modalities

CT, RTSTRUCT

Number of Patients

3346

Number of Studies

3346

Number of Series

9693

Number of Images

618837

Images Size (GB)334

Several studies have tried to address this data cleaning challenge using different approaches (Ger et al. 2018; Gjesteby et al. 2016). Recently, a convolutional neural network (CNN) was used to detect patient CT volumes containing artifacts with a precision-recall area under the curve (AUC) of (0.92) and accuracy of (98.4%) (Welch et al. 2020). However, to the author’s knowledge, no work has been done to differentiate between dental artifacts (DA) of different magnitudes or to quantify how the location of DAs could affect quantitative imaging features used to train radiomic models. Furthermore, previous DA detection studies have classified hand-drawn regions of interest (ROI) as DA positive or DA negative (REF) but have not examined the correlation between radiomic features in a given ROI and its distance from the DA source. These methods, even if effective at screening datasets for artifacts, could cause vast amounts of data to be unnecessarily marked as unclean, even if the artifacts do not homogeneously affect radiomic features in the patient’s image volume. In this study, we propose a novel two-step combinatorial algorithm to detect DAs on a per-slice basis in CT image datasets. Conventional image processing methods based on histogram-based thresholding and the CT sinogram are combined with a previously-published CNN network in order to create a three-class DA classifier and DA location detector for large radiomic datasets. This algorithm works on patient CT volumes with minimal preprocessing or manual annotation. Finally, we examined the correlation between quantitative imaging features and the physical distance between the DA and the gross tumour volume (GTV).

Inclusion: The dataset used for this study consists of 4130 head and neck cancer CT image volumes collected from 2005 to 2007 treated with definitive RT at the University Health Network (UHN) in Toronto, Canada

333



Localtab
titleCitations & Data Usage Policy

Citations & Data Usage Policy

Tcia limited license policy

Info
titleData Citation

Welch, M. L., Kim, S., Hope, A., Huang, S. H., Lu, Z., Marsilla, J., Kazmierski, M., Rey-McIntyre, K., Patel, T., O’Sullivan, B., Waldron, J., Kwan, J., Su, J., Soltan Ghoraie, L., Chan, H. B., Yip, K., Giuliani, M., Princess Margaret Head And Neck Site Group, Bratman, S., … Tadic, T. (2023). Computed Tomography Images from Large Head and Neck Cohort (RADCURE) (Version 1) [Data set]. The Cancer Imaging Archive. https://doi.org/10.7937/J47W-NM11


Info
titlePublication Citation

Kazmierski, M., Welch, M., Kim, S., McIntosh, C., Rey-McIntyre, K., Huang, S. H., Patel, T., Tadic, T., Milosevic, M., Liu, F.-F., Ryczkowski, A., Kazmierska, J., Ye, Z., Plana, D., Aerts, H. J., Kann, B. H., Bratman, S. V., Hope, A. J., & Haibe-Kains, B. (2023). Multi-institutional prognostic modelling in head and neck cancer: evaluating impact and generalizability of deep learning and radiomics. In Cancer Research Communications. American Association for Cancer Research (AACR). https://doi.org/10.1158/2767-9764.crc-22-0152


Info
titleTCIA Citation

Clark, K., Vendt, B., Smith, K., Freymann, J., Kirby, J., Koppel, P., Moore, S., Phillips, S., Maffitt, D., Pringle, M., Tarbox, L., & Prior, F. (2013).

Localtab
titleCitations & Data Usage Policy

Citations & Data Usage Policy

Tcia head license access

Info
titleData Citation

Draft DOI (not findable): 

https://doi.datacite.org/dois/10.7937/j47w-nm11

Info
titlePublication Citation
Info
titleTCIA Citation

Clark K, Vendt B, Smith K, Freymann J, Kirby J, Koppel P, Moore S, Phillips S, Maffitt D, Pringle M, Tarbox L, Prior F.  The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository, . In Journal of Digital Imaging , Volume (Vol. 26, Number Issue 6, December, 2013, pp 1045-1057. DOI: pp. 1045–1057). Springer Science and Business Media LLC. https://doi.org/10.1007/s10278-013-9622-7

Other Publications Using This Data

TCIA maintains a list of publications which leverage TCIA data. If you have a manuscript you'd like to add please contact the TCIA Helpdesk.


Localtab
titleVersions

Version 1 (Current): Updated 2023/

mm

06/

dd

14

Data TypeDownload all or Query/FilterLicense
Images (DICOM,
334 GB)

Image RemovedImage Removed

324 GB)


Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/70226325/RADCURE%20Phase%201%20release%20Jun%201%202023.tcia?api=v2



Tcia button generator
labelSearch
urlhttps://nbia.cancerimagingarchive.net/nbia-search/?MinNumberOfStudiesCriteria=1&CollectionCriteria=RADCURE



(Download requires the NBIA Data Retriever)

Tcia restricted license

Images and Radiation Therapy Structures, updated OPC-Radiomics (DICOM, 57 GB)



Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/70226325/RADCURE%20OPC%20only%20Phase%201%20manifest%20Jun%201%202023.tcia?api=v2



Tcia button generator
labelSearch
urlhttps://nbia.cancerimagingarchive.net/nbia-search/?saved-cart=nbia-22801683744260516


(Download requires the NBIA Data Retriever

(Requires NBIA Data Retriever.

)

Tcia restricted license

Clinical
Data (CSV)
data (XLSX)


Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/70226325/RADCURE_TCIA_Clinical%20June%2013%202023.xlsx?api=v2



Tcia cc by 4

Patient ID Mapping-RADCURE patient id to OPC-RADIOMICS patient id (CSV)


Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/70226325/RADCURE%20patient%20id%20to%20OPC-Radiomics%20patient%20id%20mapping.csv?api=v2
Image Removed



Tcia cc by 4