Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Summary

Redirect
delay5
locationhttps://www.cancerimagingarchive.net/collection/lung-phantom/

Excerpt

The FDA anthropomorphic thorax phantom with 12 phantom lesions of different sizes (10 and 20 mm in effective diameter), shapes (spherical, elliptical, lobulated, and spiculated), and densities (−630,−10, and +100 HU) was scanned at Columbia University Medical Center on a 64-detector row scanner (LightSpeed VCT, GE Healthcare, Milwaukee, WI). The CT scanning parameters were 120 kVp, 100 mAs, 64x0.625 collimation, and pitch of 1.375. The images were reconstructed with the lung kernel using 1.25 mm slice thickness.

...

Localtab Group



Localtab
activetrue
titleData Access

Data Access


Data TypeDownload all or Query/FilterLicense
Images (DICOM, 127.5 MB)


Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/19038256/TCIA_Lung_Phantom_06-22-2015.tcia?version=2&modificationDate=1601061652295&api=v2

Download Lung Phantom


Tcia button generator
labelSearch
urlhttps://nbia.cancerimagingarchive.net/nbia-search/?MinNumberOfStudiesCriteria=1&CollectionCriteria=Lung Phantom

Search Lung Phantom

  

(Download requires the NBIA Data Retriever)

Tcia cc by 3

DICOM Metadata Digest (CSV, 28 kB)


Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/19038256/LungPhantom_MetaData.csv?version=1&modificationDate=1495563917555&api=v2



Tcia cc by 3


Click the Versions tab for more info about data releases.

Nci_crdc additional resources

Third Party Analyses of this Dataset

TCIA encourages the community to publish your analyses of our datasets. Below is a list of such third party analyses published using this Collection:




Localtab
titleDetailed Description

Detailed Description


Collection Statistics

Updated 2014/08/26

Modalities

CT

Number of Participants

1

Number of Studies

1

Number of Series

1

Number of Images

237

Image Size (MB)127.5

Supporting Documentation and Metadata

No supporting documentation is available for this collection.





Localtab
titleCitations & Data Usage Policy

Citations & Data Usage Policy 

Tcia limited license policy

Info
titleData Citation

Zhao, BinshengB. (2015). Data From Lung _PhantomPhantom (Version 2) [Data set]. The Cancer Imaging Archive. https://doi.org/10.7937/K9k9/TCIAtcia.2015.08A1IXOO08a1ixoo


Info
titleTCIA Citation

Clark, K., Vendt, B., Smith, K., Freymann, J., Kirby, J., Koppel, P., Moore, S., Phillips, S., Maffitt, D., Pringle, M., Tarbox, L., & Prior, F. (2013).  The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository, . In Journal of Digital Imaging , Volume (Vol. 26, Number Issue 6, December, 2013, pp 1045-1057, pp. 1045–1057). Springer Science and Business Media LLC. https://doi.org/10.1007/s10278-013-9622-7 PMCID: PMC3824915


Other Publications Using This Data

TCIA maintains a list of publications that which leverage our data. At this time, we are not aware of any publications based on this data.  If you have publication  a publication you'd like to add, please  contact the contact TCIA's Helpdesk .




Localtab
titleVersions

Version 2 (Current): Updated 2020/09/25

Data TypeDownload all or Query/Filter
CT(127.5 MB)


Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/19038256/LungPhantom_MetaData.csv?version=1&modificationDate=1495563917555&api=v2



Tcia button generator
labelSearch
urlhttps://www.cancerimagingarchive.net/nbia-search/?CollectionCriteria=Lung%20Phantom


  

(Download requires the NBIA Data Retriever)

DICOM Metadata Digest (CSV)


Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/19038256/LungPhantom_MetaData.csv?version=1&modificationDate=1495563917555&api=v2



9/25/2020: Adjusted this table and *.tcia manifest files to remove segmentations built in Multi-site collection of Lung CT data with Nodule Segmentations. DOI: https://doi.org/10.7937/K9/TCIA.2015.1BUVFJR7 . Note that the "Search" will take you to both until you uncheck the "Include third party" button.

Version 1

(deprecated)

: Updated 2014/08/26

(deprecated)