Child pages
  • Segmentation of Vestibular Schwannoma from Magnetic Resonance Imaging: An Annotated Multi-Center Routine Clinical Dataset (Vestibular-Schwannoma-MC-RC)

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Summary

Redirect
delay5
locationhttps://www.cancerimagingarchive.net/collection/vestibular-schwannoma-mc-rc/

Excerpt
Image Added

The Vestibular-Schwannoma-MC-RC (VS-

Excerpt
This multi-center routine clinical (

MC-RC) dataset

consists of 165

contains longitudinal MRI scans of 160 patients with a single sporadic Vestibular Schwannoma (VS)

who were referred

from 10 medical sites

and consecutively seen at a single center. These routine clinical datasets are more diverse in terms of the tumor manifestation as well as the acquisition parameters. Using this dataset, researchers can develop and validate methods for automatic surveillance of Vestibular Schwannoma, which work robustly on images acquired at different hospitals.Patients had multiple time points

in the United Kingdom. For all patients either a T1-weighted (T1w) or T2-weighted (T2w) scan, or both, are available. The dataset provides binary segmentations of the VS for all scan sessions. The dataset comprises up to three time points for each patient resulting in a total of

446

427 timepoints and

509

487 3D-images

. 

. These timepoints represent the first, central, and last MRI exams that the patients underwent. For 60 timepoints, both T1w and T2w are available, for 64 timepoints only T1w, and for 303 timepoints only T2w. Manual ground truth segmentations were obtained in an iterative process in which segmentations were: 1) produced or amended by a specialized company; and 2) reviewed by one of three trained radiologists; and 3) validated by an expert team. Using this dataset, researchers can develop and validate methods, for example, for automatic surveillance of Vestibular Schwannoma, which work robustly on images acquired at different hospitals.

Pre-processing

The MRI images are provided in DICOM format. All images were defaced using automatic affine registration or manual landmark registration with BRAINSFit and the template and face mask provided in pydeface. Segmentations are provided in NIfTI format

Comparison to VS-SEG dataset

Compared to the

existing 

Vestibular-Schwannoma-SEG (VS-SEG

 dataset on TCIA that was obtained from

) dataset which was acquired with a standardized protocol for radiation treatment planning on a single scanner

, this dataset was acquired from multiple scanners manufactured by different vendors. This dataset also provides a refined segmentation of intrameatal and extrameatal components of the VS

at a single site, the VS-MC-RC dataset aims to capture the diversity of MRI scans encountered in a routine clinical setting; it contains a wide range of scan protocols and was acquired on multiple scanners by different manufacturers. In addition, the tumour manifestation in scans of this dataset is more diverse because it includes tumours at early stages and post-operative tumour residuals rather than only tumours specifically selected for radiation therapy.

Patient overlap with VS-SEG dataset

58 patients of the VS-MC-RC dataset were previously included in the VS-SEG dataset. These patients have a Patient ID that begins with “VS-SEG- “. Patient IDs of patients that are not part of the VS-SEG dataset begin with “VS-MC-RC-”. Please note that for most patients that are part of both datasets, the timepoints and MRI series included in one dataset are different from those included in the other dataset. However, 8 series are included in both datasets. These series are listed in the CSV file below. Please note that the VS-SEG dataset was not exported with the same software as the VS-MC-RC dataset. Therefore, the metadata of overlapping series might differ. Furthermore, different defacing algorithms were used so that pixel data of overlapping series are not the same in affected areas.

Embargoed data

This dataset is part of the challenge “Cross-Modality Domain Adaptation for Medical Image Segmentation” (crossMoDA). 126 timepoints that were included in the validation and test set of the challenge are currently under embargo and will be released in August 2024. Until then, 301 timepoints from 124 patients are available for download.

Acknowledgements

We would like to acknowledge the individuals and institutions that have provided data for this collection:

This work was supported by Wellcome Trust (203145Z/16/Z, 203148/Z/16/Z, WT106882), EPSRC (NS/A000050/1, NS/A000049/1) and MRC (MC/PC/180520) funding. Additional funding was provided by Medtronic. TV Tom Vercauteren is also supported by a Medtronic/Royal Academy of Engineering Research Chair (RCSRF1819/7/34).

Localtab Group


Localtab
activetrue
titleData Access

Data Access

Tcia head license access


Data TypeDownload all or Query/FilterLicense

Images (DICOM,

XX.X

10 GB)



Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/157287455/Vestibular-Schwannooma-MC-RC%20manifest%20August%202023.tcia?api=v2



tcia-button-generator
labelSearch
urlhttps://nbia.cancerimagingarchive.net/nbia-search/?MinNumberOfStudiesCriteria=1&CollectionCriteria=Vestibular-Schwannoma-MC-RC



(Download requires NBIA Data Retriever)

tcia-

restricted

cc-by-

license

4

NIfTI segmentation data 




Segmentations (NIfTI, zip, 3.2 MB) 


Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/157287455/VS-MC-RC-Segmentations_with_pathname_spreadsheet-Release2023.zip?api=v2



Tcia cc by 4



Mapping of series in Vestibular-Schwannoma-SEG dataset (csv, 2 KB)


Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/157287455/series_overlap_between_VS-MC-RC_and_%20VS-SEG.csv?api=v2



tcia-cc-

restricted

by-

license
Click the Versions tab for more info about data releases.

4

Note: There are 124 patients currently available in TCIA search and download; the remaining 36 patients will be available post challenge in 2024.


Related Collection:




Localtab
titleDetailed Description

Detailed Description

Image Statistics

Radiology Image Statistics

Modalities

MR

Number of Patients

160124

Number of Studies

428301

Number of Series

487354

Number of Images

22086

Images Size (GB)10

Note: There are 124 patients currently available in TCIA search and download; the remaining 36 patients will be available post challenge in 2024.


Localtab
titleCitations & Data Usage Policy

Citations & Data Usage Policy

Tcia limited license policy

Info
titleData Citation

DOI goes here. Create using Datacite with information from Collection Approval form

Info
titlePublication Citation
Info
titleAcknowledgement

Required acknowledgements only (ex:The CPTAC program requests that publications using data from this program...). If they just want to thank someone, that goes in the Acknowledgement section underneath the Summary.Kujawa, A., Dorent, R., Wijethilake, N., Connor, S., Thomson, S., Ivory, M., Bradford, R., Kitchen, N., Bisdas, S., Ourselin, S., Vercauteren, T., & Shapey, J. (2023). Segmentation of Vestibular Schwannoma from Magnetic Resonance Imaging: An Annotated Multi-Center Routine Clinical Dataset (Vestibular-Schwannoma-MC-RC) (Version 1) [dataset]. The Cancer Imaging Archive. https://doi.org/10.7937/HRZH-2N82


Info
titleTCIA Citation

Clark, K., Vendt, B., Smith, K., Freymann, J., Kirby, J., Koppel, P., Moore, S., Phillips, S., Maffitt, D., Pringle, M., Tarbox, L., & Prior, F. (2013). The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository. In Journal of Digital Imaging (Vol. 26, Issue 6, pp. 1045–1057). Springer Science and Business Media LLC.https://doi.org/10.1007/s10278-013-9622-7

Other Publications Using This Data

TCIA maintains a list of publications which leverage TCIA data. If you have a manuscript you'd like to add please contact the TCIA Helpdesk.


Localtab
titleVersions

Version 1 (Current): Updated

yyyy

2023/

mm

08/

dd

23

Data TypeDownload all or Query/FilterLicense

Images (DICOM, XX.X 10 GB)



Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/157287455/Vestibular-Schwannooma-MC-RC%20manifest%20August%202023.tcia?api=v2



Tcia button generator
labelSearch
urlhttps://nbia.cancerimagingarchive.net/nbia-search/?MinNumberOfStudiesCriteria=1&CollectionCriteria=Vestibular-Schwannoma-MC-RC



(Download requires the NBIA Data Retriever)

tcia-restrictedcc-by-license4

NIfTI segmentation data




Segmentations (NIfTI, zip) 


Tcia button generator
urlhttps://wiki.cancerimagingarchive.net/download/attachments/157287455/VS-MC-RC-Segmentations_with_pathname_spreadsheet-Release2023.zip?api=v2



Tcia cc by 4



Mapping of series in Vestibular-Schwannoma-SEG dataset (csv)


Tcia button generator
tcia-restricted-license
urlhttps://wiki.cancerimagingarchive.net/download/attachments/157287455/series_overlap_between_VS-MC-RC_and_%20VS-SEG.csv?api=v2



Tcia cc by 4

Note: There are 124 patients currently available in TCIA search and download; the remaining 36 patients will be available post challenge in 2024.