Localtab |
---|
active | true |
---|
title | Data Access |
---|
| Data AccessData Type | Download all or Query/Filter | License |
---|
Images and Radiation Therapy Structures (DICOM, 1.33 GB) |
Tcia button generator |
---|
url | https://wiki.cancerimagingarchive.net/download/attachments/24284300/CC-Radiomics-Phantom-7-28-2017-doiJNLP-2vcxNoRY.tcia?version=1&modificationDate=1534787033680&api=v2 |
---|
|
|
Tcia button generator |
---|
label | Search |
---|
url | https://www.cancerimagingarchive.net/nbia-search/?CollectionCriteria=CC-Radiomics-phantom |
---|
|
|
(Download requires the NBIA Data Retriever) | |
Click the Versions tab for more info about data releases. |
Localtab |
---|
title | Detailed Description |
---|
| Detailed Description | |
---|
Modalities | CT, RTSTRUCT | Number of Patients | 17 | Number of Studies | 17 | Number of Series | 51 | Number of Images | 2672 | Image Size (GB) | 1.33 |
Acquisition parameters for the phantom scans in this Collection: Scan | Manufacturer | Model | Kernel | Type | Slice Thickness (mm) | Pixel (mm) | Spiral Pitch Factor | kVp | Effective mAs | CTDIvol (mGy) | CCR1-GE1 | GE | Discovery CT750 HD | standard | helical | 2.5 | 0.49 | 0.98 | 120 | 81 | 6.19 | CCR1-GE2 | GE | Discovery CT750 HD | standard | axial | 2.5 | 0.70 | 1.00 | 120 | 300 |
| CCR1-GE3 | GE | Discovery CT750 HD | standard | helical | 2.5 | 0.78 | 0.98 | 120 | 122 | 9.3 | CCR1-GE4 | GE | Discovery ST | standard | helical | 2.5 | 0.98 | 1.35 | 120 | 143 | 16.3 | CCR1-GE5 | GE | LightSpeed RT | standard | helical | 2.5 | 0.98 | 0.75 | 120 | 1102 | 53.6 | CCR1-GE6 | GE | LightSpeed RT16 | standard | helical | 2.5 | 0.98 | 0.94 | 120 | 367 | 18.8 | CCR1-GE7 | GE | LightSpeed VCT | standard | helical | 2.5 | 0.74 | 0.98 | 120 | 82 |
| CCR1-P1 | Philips | Brilliance Big Bore | B | helical | 3.0 | 0.98 | 0.94 | 120 | 320 | 17.8 | CCR1-P2 | Philips | Brilliance Big Bore | C | helical | 3.0 | 0.98 | 0.94 | 120 | 369 | 15.8 | CCR1-P3 | Philips | Brilliance Big Bore | B | helical | 3.0 | 1.04 | 0.81 | 120 | 320 | 19.9 | CCR1-P4 | Philips | Brilliance Big Bore | B | helical | 3.0 | 1.04 | 0.81 | 120 | 369 | 19.9 | CCR1-P5 | Philips | Brilliance 64 | B | helical | 3.0 | 0.98 | 0.67 | 120 | 372 | 16.4 | CCR1-S1 | Siemens | Sensation Open | B31s | axial | 3.0 | 0.54 | 1.00 | 120 | 26 - 70 | 1.5 | CCR1-S2 | Siemens | SOMATOM Definition Flash | ['I70f', '2'] | helical | 2.0 | 0.52 | 0.60 | 120 | 17 - 28 |
| CCR1-T1 | Toshiba | Aquilion | FC18 | helical | 3.0 | 0.63 | 1.11 | 120 | 135 | 4.0 | CCR1-T2 | Toshiba | Aquilion | FC18 | helical | 3.0 | 0.63 | 1.11 | 120 | 135 | 3.8 | CCR1-T3 | Toshiba | Aquilion ONE | FC18 | helical | 3.0 | 0.98 | 0.99 | 120 | 151 | 13.5 |
|
Localtab |
---|
title | Citations & Data Usage Policy |
---|
| Citations & Data Usage Policy Tcia limited license policy |
---|
Info |
---|
| Mackin, D., Ray, X., Zhang, L., Fried, D., Yang, J., Taylor, B., Rodriguez-Rivera, E., Dodge, C., Jones, A., & Court, L. (2017). Data From Credence Cartridge Radiomics Phantom CT Scans (CC-Radiomics-Phantom) [Data set]. The Cancer Imaging Archive. https://doi.org/10.7937/K9/TCIA.2017.zuzrml5b |
Info |
---|
| Clark, K., Vendt, B., Smith, K., Freymann, J., Kirby, J., Koppel, P., Moore, S., Phillips, S., Maffitt, D., Pringle, M., Tarbox, L., & Prior, F. (2013). The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository. In Journal of Digital Imaging (Vol. 26, Issue 6, pp. 1045–1057). Springer Science and Business Media LLC. https://doi.org/10.1007/s10278-013-9622-7 PMCID: PMC3824915 |
Additional Publication Resources:The Collection authors suggest the below will give context to this dataset: Mackin, D., Fave, X., Zhang, L., Fried, D., Yang, J., Taylor, B., Rodriguez-Rivera, E., Dodge, C., Jones, A. K., & Court, L. (2015). Measuring Computed Tomography Scanner Variability of Radiomics Features. In Investigative Radiology (Vol. 50, Issue 11, pp. 757–765). Ovid Technologies (Wolters Kluwer Health). https://doi.org/10.1097/rli.0000000000000180 The following paper was generated on different imaging modalities but the same phantom, this is a related but independent paper with a different set of authors: Fave, X., Mackin, D., Yang, J., Zhang, J., Fried, D., Balter, P., Followill, D., Gomez, D., Kyle Jones, A., Stingo, F., Fontenot, J., & Court, L. (2015). Can radiomics features be reproducibly measured from CBCT images for patients with non-small cell lung cancer? In Medical Physics (Vol. 42, Issue 12, pp. 6784–6797). Wiley. https://doi.org/10.1118/1.4934826
Other Publications Using This DataTCIA maintains a list of publications which leverage our data. If you have a manuscript you'd like to add please contact TCIA's Helpdesk. |
Localtab |
---|
| Version 1 (Current): Updated 2017/07/28Data Type | Download all or Query/Filter | License |
---|
Images (DICOM, 1.33 GB) |
Tcia button generator |
---|
url | https://wiki.cancerimagingarchive.net/download/attachments/24284300/CC-Radiomics-Phantom-7-28-2017-doiJNLP-2vcxNoRY.tcia?version=1&modificationDate=1534787033680&api=v2 |
---|
|
|
Tcia button generator |
---|
label | Search |
---|
url | https://www.cancerimagingarchive.net/nbia-search/?CollectionCriteria=CC-Radiomics-phantom |
---|
|
|